SAVE THESE INSTRUCTIONS 

Cocoon Fires is very safety conscious and we have taken every care in designing, manufacturing 
ring and assembling your Cocoon Fires Burner to ensure it operates effectively, efficiently and safely. Please 
exercise care when using this product and follow the instructions below. Cocoon Fires cannot be held 
responsible for any damage or injury caused if the information supplied in this manual are not adhered to. 

WARNING - IMPORTANT SAFEGUARDS 

Read all instructions and warnings before installation and use. 

 

NEVER LEAVE THE APPLIANCE UNATTENDED DURING OPERATION OR WHEN A FLAME IS PRESENT.  

 

DO NOT IGNITE THE COMBUSTION CHAMBER WHEN IT IS IN A HOT STATE. 

 

THIS PRODUCT IS TO BE USED ONLY IN ROOMS ACCORDING TO THE MANUAL. 

 

KEEP AWAY FROM CHILDREN. 

 

STORAGE OF YOUR FUEL IS TO BE DONE IN ACCORDANCE WITH NATIONAL AND/OR REGIONAL 
REGULATIONS. 

 

THIS PRODUCT IS FOR DECORATIVE AND DOMESTIC USE ONLY. 

 

NOT SUITABLE FOR CONTINUOUS OPERATION. 

 

OPERATION OF SEVERAL APPLIANCE IN ONE ROOM IS ONLY ALLOWED IF THE POWER OUTPUT IS EQUAL TO 
OR LOWER THAN 4,5 kW/h AND ADDITIONAL VENTILATION IS REQUIRED IF THIS IS EXCEEDED. 

 

DO NOT OVERFILL THE BURNER’S INTENDED CAPACITY.

 

 

OVERFILLING WILL CAUSE THE APPARATUS TO BURN AT HIGHER TEMPERATURE RATES RESULTING IN THE 
APPARATUS BEING DIFFICULT TO TURN OFF. 

 

DO NOT INSTALL INTO AN AREA WHERE THERE IS A DRAFT WHICH CAN AFFECT THE FLAME. 

 

USE ONLY THE FUEL FOR WHICH THE COMBUSTION CHAMBER IS INTENDED. 

 

DO NOT TOUCH THE EXTERIOR OF THE CHIMENEA AND THE BURNER DURING OR AFTER BURNING. 

 

PARTS OF THIS CHIMENEA AND ESPECIALLY THE COMBUSTION CHAMBER CAN REACH HIGH TEMPERATURES 
DURING OPERATION. 

 

DO NOT COVER NOR MOVE THE COMBUSTION CHAMBER OR CHIMENEA DURING OPERATION. 

 

DO NOT HAVE COMBUSTIBLE OBJECTS IN CLOSE PROXIMITY TO THE CHIMENEA. 

 

NEVER POSITION THE BURNER WITHIN RANGE OF COMBUSTIBLE ITEMS THAT CAN BE MOVED/BUMPED BY 
ACCIDENT OR BLOWN BY THE WIND. e.g. CURTAINS, PAPERS & BLANKETS. 

 

ONLY USE THE CHIMENEA IN AREAS WITH GOOD VENTILATION. 

 

DRAFT AREAS WILL CAUSE THE APPARATUS TO BURN AT HIGHER TEMPERATURE RATES RESULTING IN THE 
APPARATUS BEING DIFFICULT TO TURN OFF, THEREFORE THE APPARATUS SHOULD NOT BE USED IN A DRAFT 
AREA. 

 

DO NOT COVER THE CHIMENEA VENT WITH ANY DECORATIVE ITEMS WHETHER THEY ARE COMBUSTIBLE OR 
NON-COMBUSTIBLE, INCLUDING BUT NOT LIMITED TO ARTIFICIAL LOGS, STONES, PEBBLES, GLASS BEADS etc.  

 

THIS APPARATUS HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET, TO REDUCE THE RISK OF FIRE OR 
INJURY, DO NOT INSTALL AN UNVENTED GAS LOG SET INTO THIS APPLIANCE. 

 

WARNING: FILLING AN ALCOHOL FUELLED DEVICE WHILE LIT HAS CAUSED SEVERE BURNS AND DEATHS. YOU 
MUST REMOVE THE FUEL TANK FROM THE DEVICE BEFORE REFILLING. WHEN REFILLING FIRST CHECK THE 
FLAME IS EXTINGUISHED AND THAT THE DEVICE IS COOL. 

 

NEVER FILL OR REFILL THE BURNER OVER OR NEAR AN OPEN FLAME. 

 
 

CAUTION

 

 

Make sure you have read and understood this manual before using this product.  

 

If fuel is spilt onto the surface 

WIPE IT IMMEDIATELY WITH A DRY CLOTH AND LEAVE TO DRY BEFORE LIGHTING THE 

BURNER.

 

 

If the Burner is accidentally overfilled, follow the steps in the manual to rectify. 

 

In Australia is it mandatory for all products to be supplied with a Fuel Canister which has a flame arrestor. Cocoon 
Fires supplies a fuel cannister with a flame arrestor in the Australian market. We recommend in all markets to use a 
fuel cannister with a flame arrestor. 

 

To refill, wait until the Burner is at the room temperature after the flame has been turned off.  

 

NOTE: the flame may not be visible to the naked eye in daylight and must be cool before filling. 

 

NEVER refill over or near an open flame and use a decanter with a flame arrestor only.  

 

Remove all plastic & packaging before using the fireplace. 

 

Содержание CFTB

Страница 1: ...Operating Manual COCOON TERRA STANDING MODEL Corresponding Model Codes CFTB CTSS PLEASE READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE OPERATING THIS PRODUCT ...

Страница 2: ...MABER PARTS NAMES AND DESCRIPTIONS Page 6 SAFETY CLEARANCE Page 7 8 TERRA STANDING MODEL INSTALLATION ADJUSTMENTS Page 9 13 TROUBLESHOOTING AND OPERATIONAL TIPS Page 14 OPERATING THE COCOON BURNER Page 15 PROCEDURE IF BURNER IS OVERFILLED AND CAUTION Page 16 IGNITING THE COMBUSTION CHAMBER Page 17 REGULATING AND EXTINGUISHING THE FLAME Page 18 TO REFILL THE COMBUSTION CHAMBER Page 19 WARNING Page ...

Страница 3: ...STIBLE OBJECTS IN CLOSE PROXIMITY TO THE CHIMENEA NEVER POSITION THE BURNER WITHIN RANGE OF COMBUSTIBLE ITEMS THAT CAN BE MOVED BUMPED BY ACCIDENT OR BLOWN BY THE WIND e g CURTAINS PAPERS BLANKETS ONLY USE THE CHIMENEA IN AREAS WITH GOOD VENTILATION DRAFT AREAS WILL CAUSE THE APPARATUS TO BURN AT HIGHER TEMPERATURE RATES RESULTING IN THE APPARATUS BEING DIFFICULT TO TURN OFF THEREFORE THE APPARATU...

Страница 4: ...nfires com www cocoonfires com PARTS NAMES AND DESCRIPTIONS Combustion chamber Mount Plate Removable Tray Bracket Main Body Legs For standing model 3 security hex nuts to secure legs to main body Combustion Chamber ...

Страница 5: ... by sliding the Sliding Lid backwards and forwards and also to extinguish the flame by sliding the Sliding Lid into the closed position The Lifting Handles are supplied in order to remove the Combustion Chamber for refilling They should never be used while there is still a flame in the Combustion Chamber or at high temperature Wait 45 minutes after the Combustion chamber has been turned off before...

Страница 6: ...To use the handle correctly to lift the Combustion Chamber in and out of the Mount Plate inside the Main Body follow the instructions below It is very important than when handling the Combustion Chamber with the Lifting Handles that the combustion chamber be kept as level as possible to avoid spilling of fuel With the handle in the closed position lower the flat tabs at the bottom of the Lifting H...

Страница 7: ... info cocoonfires com www cocoonfires com COMBUSTION CHAMBER PARTS NAMES AND DESCRIPTIONS Combustion Chamber Top Plate Sliding Lid Burner Vent Filling Line Fuel Tank Handle Holes Vent Plate Filling Line ...

Страница 8: ... able to support a minimum mass of 150 kg 330 lb or more Total product weight is 30 kg 66 1 lb Floor surface must be solid true and level The legs must not wobble MINIMUM DISTANCES A 10 2 cm 4 in min to non combustible material B 102 cm 40 in min C 102cm 40 in min distance to combustible items D 3 8 cm 1 5 in min to non combustible wall Chiminea Opening ensure no combustible materials within 1 met...

Страница 9: ...ustible material NOT be within the reach of any objects that are not fixed in position and can be moved by the wind or bumped over easily i e curtains blankets newspapers etc KEEP HANDY A CLASS ABE FIRE EXTINGUISHER USE CORRECT FUEL BIOETHANOL FUEL IS TO BE STORED IN A FIRE SAFE AREA AND IS TO BE DONE IN ACCORDANCE WITH NATIONAL AND OR REGIONAL REGULATIONS WARNING In a house of typical constructio...

Страница 10: ...surface on which the Legs stands must be a rigid surface that is flat level and secure hex nut hex nut With the Legs securely attached to the Main Body place the Removable Tray Bracket over the threaded stud at the base of the Main Body and then tighten in place with the hex nut supplied to be finger tight Now follow the adjustment procedures on the following pages before securing with an appropri...

Страница 11: ... Main Body and therefore critical to the proper functioning of the Combustion Chamber With the Removable Tray Bracket and hex type nut loosely in place adjust the Removable Tray Bracket backwards or forwards so that the front edge of the Mount Plate A sits just below the front bottom lip of the opening in the Main Body B Once this adjustment is done then tighten the hex type nut to secure the Remo...

Страница 12: ...e are critical to the airflow inside the Main Body and therefore critical to the proper functioning of the Combustion Chamber B A By finely adjusting the Removable Tray Bracket backward and forward 1 allows for the necessary adjustment in height 2 of the Mount Plate NOTE the front edge of the Mount Plate A must be just below the front bottom lip of the opening in the Main Body B 1 2 2 A B ...

Страница 13: ...can be achieved by loosening the 6 hex nuts below the Mount Plate and sliding the Safety Tank front to back slightly Always make sure that the Safety Tank below the Mount Plate is properly secured after this adjustment NOTE every time you fill the Combustion Chamber this Safety Tank should be checked for residual fuel to ensure that there is no fuel leaking from the Fuel Tank ...

Страница 14: ...e Mount Plate opening using the Lifting Handles supplied as shown on the previous pages Your Cocoon Burner is now ready to use follow the steps on the following pages to correctly and safely fill ignite adjust shut off and refill the Combustion Chamber Always make sure the Lifting Handles are removed from the Combustion Chamber as shown above when it is not in use otherwise these parts will become...

Страница 15: ...wnward force in quick succession Never blow on the flame whilst the Sliding Lid is in an open position If after some time you find the Sliding Lid has become sticky when attempting to move it then remove the Sliding Lid from its housing and rub the underside using the green side of a Scotch Bright scouring pad Take care to only scrub in the direction of the brushing lines of the stainless steel Ma...

Страница 16: ...3 02 35m2 0 39 L H 3 5 Hours To fill the Combustion Chamber remove it from the Main Body using the Lifting Handles and pour fuel inside the Vent Opening being careful not to spill Fill up to the fill line as indicated in red with no more than 1 5L of fuel 3 5 hrs burning time After filling is done wipe away any spilled or excess fuel before returning the Combustion Chamber to the Mount Plate openi...

Страница 17: ... lifting Handles Empty the excess fuel into a suitable container Wipe off all excess fuel that may have dripped on the outside of the Combustion Chamber during emptying and allow any residual fuel to evaporate Leave for 1 hour Place the Combustion Chamber back into Chimenea Ignite the Combustion Chamber only once all residual fuel outside the Combustion Chamber has completely evaporated and the co...

Страница 18: ...Chamber and the Combustion Chamber has been placed back inside the Chimenea as indicated above it is safe to consider igniting the Combustion Chamber Using a long arm fire lighter and standing at a safe distance from the Combustion Chamber carefully introduce a flame as indicated above to ignite the Combustion Chamber Always make sure there is a Class ABE fire extinguisher close at hand when ignit...

Страница 19: ...n Chamber and slide backwards or forwards to regulate the flame size To extinguish the flame insert the tips of the Sliding Lid Handle into the holes of the Sliding Lid of the Combustion Chamber and slide all the way forward until the flame is extinguished Should the flame not extinguish with the first try please repeat until extinguished It should be a swift action coupled with downward pressure ...

Страница 20: ...on surfaces is recommended as per section called TROUBLESHOOTING OPERATIONAL TIPS 2 Checking operation of Sliding Lid shutoff device should be done regularly 3 Make sure the Sliding Lid from the Combustion Chamber slides correctly smoothly and fully every time before igniting the Combustion Chamber Cleaning Make sure the fireplace has cooled completely before cleaning Black Models To clean dust wi...

Страница 21: ...r C Is in the original container for the specific alcohol Fuel 2 Never store fuel in the living space same location as the appliance 3 Due to high surface temperatures keep children clothing and furniture away 4 Risk of Indoor Air Pollution Use unvented decorative appliance only in well ventilated areas and with door of adjacent room open Do not obstruct air flow to the fuel holder box by piling l...

Страница 22: ...21 info cocoonfires com www cocoonfires com info cocoonfires com www cocoonfires com ...

Отзывы: