METRIC/IMPERIAL MODES:

  If the computer is computing and displaying 

in Metric, the “METRIC” legend will be illuminated when the computer is 
on.  Metric/Imperial selection is made using the Analyst

®

 software.  

Changing Modes does not affect any profiles or data stored in the 
computer. 

LOW BATTERY INDICATIONS:

 Fresh batteries should read about 3.2 

volts on the Information Screen.  When the battery voltage drops to 2.5 
volts, the “BATT” legend will be illuminated.  It is recommended to change 
the batteries at this point, but several dives might still remain possible.  
When the battery voltage decays to 2.2 volts, the “BATT” legend will begin 
to flash on and off.  Once the “BATT” legend begins to flash the 
TACLITE™ is deactivated, to conserve the remaining battery power even 
though the unit may be on a dive, and can not be activated until fresh 
batteries are installed.  While there should be sufficient battery power to 
normally complete a dive, it is not recommended to begin a new dive until 
fresh batteries are installed.  After the computer automatically turns itself 
off 70 minutes after a dive, it cannot be turned back on if the battery 
voltage is less than 2.0 volts.  Fresh batteries must be installed.  See the 
“BATTERY CHANGES” section of this manual for detailed information on 
how to change batteries.  

CAUTION!!!

  COMPLETE LOSS OF BATTERY POWER MAY CAUSE 

ALL PREVIOUS DIVE NITROGEN LOADING TO BE LOST.  THIS WILL 
AFFECT NITROGEN CALCULATIONS ON NEAR-FUTURE DIVES.  
AFTER A BATTERY CHANGE, CONFIRM THAT NO-DECOMPRESSION 
TIME DATA IS REASONABLE IN THE PRE-DIVE PREDICTION MODE.  
DIVE-OF-DAY NUMBER GOING TO ZERO IMMEDIATELY AFTER 
CHANGING BATTERIES IS ANOTHER INDICATION OF A LOSS OF 
NITROGEN LOADING. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 3  

Содержание COMMANDER EMC-20H

Страница 1: ...________ Your Name ____________________________ Your Contact __________________________ ______________________________________ ______________________________________ Purchase Date ____________________...

Страница 2: ......

Страница 3: ...s the EMC 16 first recognizes a turn on command it begins a Diagnostic function where many aspects of the system will be exercised and tested This procedure takes about three seconds and an audible be...

Страница 4: ...ING legend and REMAIN TIME digits will flash By immediately ascending to a shallower depth the diver may avoid a required decompression stop Temperature is measured for two purposes One is to compensa...

Страница 5: ...his instrument to be used for deliberate Decompression diving POST DIVE INTERVAL During the first ten minutes or up to thirty minutes if the unit is in the Training Mode after a dive the EMC 16 is in...

Страница 6: ...bridge Contacts 1 2 to access the CLoCk Time or Alarm setting screen 5 Shorting Contacts 1 2 with a coin will cause the first digit of the minutes to flash 6 Shorting Contacts 2 3 with a coin will in...

Страница 7: ...e unit will compute and display the maximum safe time and the calculated PO2 value at that depth The EMC 16 s PreDive Prediction starts at 30 feet and increases in 10 feet increments PreDive Predictio...

Страница 8: ...k is accessed via the Touch Contact Programming see page 4 This enables the diver to view dive statistics the EMC 16 has the ability to provide diving data for the most recent 1024 dives The most rece...

Страница 9: ...s having errors the display will alternate between S d or S and S t This warning will be issued whether the computer is in the Surface Interval Dive Mode Decompression Mode or Post Dive Interval In th...

Страница 10: ...to as the Normal or Bottom Gas Blend and the Decompression Gas Blend Commonly the Bottom Gas Blend is used from initial entry into the water and for most of the time spent during the dive The Normal G...

Страница 11: ...sound Ascent Rate for Deco Predictions 20 to 60 This option allows the diver to select the ascent rate to be used in the forecasting of the displayed Total Decompression time The EMC 16 is shipped fro...

Страница 12: ...rom a minimum of 10 minutes to a maximum of 30 minutes in one minute increments As shipped from the factory this is set to 10 This option can only be set via the Professional Edition of the Analyst Se...

Страница 13: ...Reorient or relocate the receiving antenna of the affected radio or television Increase the separation between the equipment and the affected receiver Connect equipment and the affected receiver to p...

Страница 14: ...ithm The EMC 16 allows the diver to input an added degree of conservatism to the nitrogen algorithm from 0 to 50 percent in one percent increments This can be done via the Touch Contact Programming Mo...

Страница 15: ...ttery power even though the unit may be on a dive and can not be activated until fresh batteries are installed While there should be sufficient battery power to normally complete a dive it is not reco...

Страница 16: ...11 Dive Mode Alternate Screen FO2 Mode 2 12 Ascent Bar Graph 2 14 PreDive Prediction FO2 Mode 5 15 PO2 Warning Display FO2 Mode 7 16aDeco Mode Primary Screen FO2 Mode Total Time 3 16cDeco Mode Primar...

Страница 17: ......

Страница 18: ...www divecochran com Cochran EMC 16 Owner s Manual English Imperial Ver EMC16FO2 3 00 1758 Firman Drive Richardson Texas 75081 USA Phone 972 644 6284 Fax 972 644 6286 www divecochran com...

Отзывы: