![Cobra Maxilift 5500 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/cobra/maxilift-5500/maxilift-5500_use-and-maintenance-manual_2630560029.webp)
25
The following table shows all the displayed alarm codes.
Display
Alarm Type
Valve on which the alarm is detected
O1A
open circuit
EV on/off 1A (CLOCKWISE ROTATION)
O1b
open circuit
EV on/off 1b (COUNTER-CLOCKWISE ROTATION)
O2A
open circuit
EV on/off 2A (BOOM UP)
O2b
open circuit
EV on/off 2b (BOOM DOWN)
O3A
open circuit
EV on/off 3A (TELESCOPIC BOOM OUT)
O3b
open circuit
EV on/off 3b (TELESCOPIC BOOM IN)
O4A
open circuit
EV on/off 4A (WINCH DOWN)
O4b
open circuit
EV on/off 4b (WINCH UP)
O_3
open circuit
E3
O_4
open circuit
E4
O_r
open circuit
VR (proportional valve)
The system, through simple operations, allows to enter other menus, which can be helpful for the operator
or a technician from the After-Sales Service.
These menus are:
-
MICRO-SWITCHES AND PRESSURE SWITCH DISPLAY MENU
-
CURRENT DISPLAY MENU (for proportional valve adjustment)
-
REMOTE CONTROL KEYBOARD DISPLAY MENU
-
WORK PRESSURE DISPLAY MENU
The following calibration and regulation menus need specific qualification and are exclusively
used by authorized workshops:
-
RAMP AND CURRENT CALIBRATION MENU
-
MOMENTUM LIMITER THRESHOLD VALUE SELF-LEARNING MENU
-
SYSTEM TYPE SETTING MENU (SINGLE-FUNCTION – DUAL MODE)
-
MOMENTUM LIMITER TYPE SETTING MENU
-
RFID (Radio Frequency Identifier) CODE LEARNING MENU