Quick Evaluation Before Installation

This section provides you with basic information about the
inverter and how to check its performance before installation.

Be sure to have on hand:

£

A 12 volt DC power source (such as a vehicle battery).

The power source must provide
between 11 and 15 volts DC and 
be able to supply enough current to
run the test load. As a rough guide,
divide the wattage of the test load by
10 to get the current (in amperes)
the power source must deliver.

£

Cables to connect the power source to the inverter 
(not included).

The cables must be as short and thick as possible in
order to reduce the voltage drop between the power
source and the inverter when it is drawing current 
from the power source.

If the cable suffers an excessive voltage drop, the inverter
may shut down when drawing higher currents because
the voltage at the inverter dropped below 10 volts.

#4 AWG stranded copper cable is recommended. 
It should be no longer than four feet (one and one-half
meters). 

The end of the cable that connects to the inverter 
must have its insulation stripped off for about 
one-half inch (one and one-half cm) back from 
the end, exposing the bare copper.

The other end of the cable, which connects to the power
source, must be terminated with a lug or other connector
that provides a secure, low resistance connection. 

For example, if the power source is a battery, the cable
must be terminated with a battery terminal that clamps
to the post on the battery. 

Power Source

£

A test load that can be plugged into the AC receptacle on
the inverter for short term testing at a low power level.
The following cables are recommended for testing low
power level test loads only.

Test Load 

Minimum

Power

Cable Size

100W

# 16 AWG copper

250W

# 12 AWG copper

500W

# 8 AWG copper

To check your inverter’s performance before installation:

1. Turn the inverter off (see page 14

for details). If the power source is
a DC power supply, switch it off
as well.

2. Connect cables to power input

terminals (see page 8 for details).

3. Connect cables to power source

(see page 8 for details).

4. Check to make sure all

connections are secure.

5. Turn the inverter on. If the power

source is a DC power supply,
switch it on first.

6. Plug in the test load.

The inverter should supply power 
to the load. If the inverter is not
working properly, refer to the
troubleshooting guide on page 20 
or power and protection indicators
section on page 16.

NOTE A USB device can be
used to check the output 
of the USB Outlet.

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Test Load

Power Button

Connect Terminals

Power Button

Connect Test Load

USB Outlet

Connect Power Source

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

10275_CPI1575_PH3  8/14/07  8:38 AM  Page 4

Содержание CPI 1575

Страница 1: ...further assistance after reading this manual Cobra Electronics offers the following customer assistance services For Assistance in the U S A Automated Help Desk English only 24 hours a day 7 days a we...

Страница 2: ...Thanks to You A1 Customer Assistance A1 Product Features A2 Important Safety Information 1 Quick Evaluation Before Installation 4 Installation Installation Requirements 6 Mounting 7 Connecting Cables...

Страница 3: ...tements in the manual CAUTION Statements specify conditions which could cause damage to the unit or other equipment WARNING Statements identify conditions that could result in personal injury or loss...

Страница 4: ...ery chargers for battery packs used in hand power tools These chargers have a WARNING label stating that dangerous voltages are present at the battery terminals This problem does not occur with the va...

Страница 5: ...ce connection For example if the power source is a battery the cable must be terminated with a battery terminal that clamps to the post on the battery Power Source A test load that can be plugged into...

Страница 6: ...lt CAUTION The inverter must only be connected to batteries with a nominal output voltage of 12 volts It will not work with a 6 volt battery and will be damaged if it is connected to a 16 volt battery...

Страница 7: ...ry 1 Press the Power Button on the inverter to the off position If the power source is a DC power supply switch it off as well 2 On the end of the cable that connects to the inverter strip back the in...

Страница 8: ...result Thoroughly ventilate the battery compartment before making this connection b Connect the cable from the Positive Red Terminal of the inverter to the Positive Terminal of the power source the ba...

Страница 9: ...ed running time in hours Power x Operating Time Watt Hours 4 Divide the watt hours by 10 to determine how many battery 12 volt ampere hours will be consumed Ground Wiring There is a screw on the rear...

Страница 10: ...amperes from the battery This is low current draw It would take more than a week to discharge a 100 ampere hour battery at this rate depending on the age of the battery Remote On Off Switch An optiona...

Страница 11: ...utput of the inverter is short circuited for one second or more it will shut down to protect itself The meter will flash as shown to indicate Short Circuit Protect and an alarm will sound To restore n...

Страница 12: ...over discharged It will restart when the input voltage exceeds 12V 0 3V The inverter will also shut down if the input voltage exceeds 15 5V 0 5V This protects the inverter against excessive input vol...

Страница 13: ...es as the load increases The unit is completely insulated in input and output for added safety Troubleshooting Guide Intro Operation Customer Assistance Warranty Notes Notice Main Icons Secondary Icon...

Страница 14: ...rning Installation Customer Assistance Limited Two Year Warranty For Products Purchased in the U S A Cobra Electronics Corporation warrants that its Cobra power inverter and the component parts thereo...

Страница 15: ...om the main menu 8 00 a m to 6 00 p m CT Monday through Friday Make check or money order payable to Cobra Electronics Attn Accessories Dept 6500 West Cortland Street Chicago IL 60707 USA To order onli...

Отзывы: