background image

o

Operation

Customer
Assistance

Warranty

Notes

Notice

ons

Caution

Warning

Installation

3

Nothing 

Comes Close to a Cobra

2

Important Safety Information

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Introduction

WARNING Power inverters contain components 
that tend to produce arcs or sparks. To prevent 
fire or explosion, do not install the inverter in 
areas or compartments containing batteries or
flammable materials or in locations that require
ignition-protected equipment.

WARNING To reduce the risk of fire, do not cover 
or obstruct the ventilation openings. Do not install
inverter in zero-clearance compartment.

Caution: Rechargeable Appliances

Certain chargers for small nickel cadmium batteries 
can be damaged if connected to the Cobra 1500 watt
inverter. Two particular types of equipment are 
prone to this problem: 

1. Small battery-operated appliances

such as flashlights, razors, and
night lights that can be plugged
directly into an AC receptacle to
recharge.

2. Certain battery chargers for

battery packs used in hand 
power tools. These chargers have
WARNING label stating that
dangerous voltages are present 
at the battery terminals.

This problem does not occur with the vast majority of
battery operated equipment. Most use a separate charger
or transformer that is plugged into the AC receptacle and
produces a low voltage output. If the label on the AC
adapter or charger states that it produces a low voltage 
AC or DC output (less than 30 volts), the inverter will 
have no problem powering the adapter safely.

Cobra 1500 Watt Output Waveform

Some very sensitive electronic equipment may not operate
satisfactory on “square wave” or “modified sine wave.” 

The output waveform is referred to as “square wave” or
“modified sine wave.” It is a stepped waveform designed
to have characteristics similar to the sine wave shape of
utility power.

A waveform of this nature is suitable for most AC loads
(including linear and switching power suppliers used in
electronic equipment, transformers and motors).

Important Safety Information

Intro

Operation

Customer
Assistance

Warranty

Notes

Notice

Main Icons

Secondary Icons

Caution

Warning

Installation

Introduction

Plug In Directly

Dangerous Voltages

10275_CPI1575_PH3  8/14/07  8:37 AM  Page 2

Содержание CPI 1575

Страница 1: ...further assistance after reading this manual Cobra Electronics offers the following customer assistance services For Assistance in the U S A Automated Help Desk English only 24 hours a day 7 days a we...

Страница 2: ...Thanks to You A1 Customer Assistance A1 Product Features A2 Important Safety Information 1 Quick Evaluation Before Installation 4 Installation Installation Requirements 6 Mounting 7 Connecting Cables...

Страница 3: ...tements in the manual CAUTION Statements specify conditions which could cause damage to the unit or other equipment WARNING Statements identify conditions that could result in personal injury or loss...

Страница 4: ...ery chargers for battery packs used in hand power tools These chargers have a WARNING label stating that dangerous voltages are present at the battery terminals This problem does not occur with the va...

Страница 5: ...ce connection For example if the power source is a battery the cable must be terminated with a battery terminal that clamps to the post on the battery Power Source A test load that can be plugged into...

Страница 6: ...lt CAUTION The inverter must only be connected to batteries with a nominal output voltage of 12 volts It will not work with a 6 volt battery and will be damaged if it is connected to a 16 volt battery...

Страница 7: ...ry 1 Press the Power Button on the inverter to the off position If the power source is a DC power supply switch it off as well 2 On the end of the cable that connects to the inverter strip back the in...

Страница 8: ...result Thoroughly ventilate the battery compartment before making this connection b Connect the cable from the Positive Red Terminal of the inverter to the Positive Terminal of the power source the ba...

Страница 9: ...ed running time in hours Power x Operating Time Watt Hours 4 Divide the watt hours by 10 to determine how many battery 12 volt ampere hours will be consumed Ground Wiring There is a screw on the rear...

Страница 10: ...amperes from the battery This is low current draw It would take more than a week to discharge a 100 ampere hour battery at this rate depending on the age of the battery Remote On Off Switch An optiona...

Страница 11: ...utput of the inverter is short circuited for one second or more it will shut down to protect itself The meter will flash as shown to indicate Short Circuit Protect and an alarm will sound To restore n...

Страница 12: ...over discharged It will restart when the input voltage exceeds 12V 0 3V The inverter will also shut down if the input voltage exceeds 15 5V 0 5V This protects the inverter against excessive input vol...

Страница 13: ...es as the load increases The unit is completely insulated in input and output for added safety Troubleshooting Guide Intro Operation Customer Assistance Warranty Notes Notice Main Icons Secondary Icon...

Страница 14: ...rning Installation Customer Assistance Limited Two Year Warranty For Products Purchased in the U S A Cobra Electronics Corporation warrants that its Cobra power inverter and the component parts thereo...

Страница 15: ...om the main menu 8 00 a m to 6 00 p m CT Monday through Friday Make check or money order payable to Cobra Electronics Attn Accessories Dept 6500 West Cortland Street Chicago IL 60707 USA To order onli...

Отзывы: