Cobra CB6 Скачать руководство пользователя страница 14

12 

NOTE: 
All  maintenance  operations  should  only be  carried 
out by a qualified service person. 

 
To achieve the best results cleaning must be regular 
and thorough and all controls and mechanical 
parts should be checked and adjusted periodically 
by a qualified service person.  If any small faults 
occur, have them attended to promptly.  Don't wait 
until they cause a complete breakdown.  It is 
recommended that the appliance is serviced every 
6 months. 
 

The gas control valve should be dismantled and 
greased every 6 months to ensure the correct  
operation of the gas control valve. 
 
To carry out this operation;- 
a.  Remove the gas control knobs from the gas tap 

spindles by pulling the knobs away from the  
control panel. 

b.  Remove the drip tray from the appliance. 
c.  Remove the two screws on the underside of the 

control panel, securing the control panel to the 
hob. 

d.  Remove the control panel from the front of the 

appliance. 

e.  Remove the 2 screws holding shaft plate to gas 

control body and remove control shaft and 
plate.  Note orientation of shaft for correct  
re-assembly. 

f.  Using needle nose pliers or similar, pull out gas 

control spindle, again noting its orientation. 

g.  Apply a suitable high temperature gas cock 

grease or lubricant such as ROCOL - A.S.P (Anti 
scuffing paste) / Dry Moly Paste to the outside of 
spindle. 

h.  Replace spindle and re-assemble the gas  

control in reverse order. 

i.  Refit the control panel to the appliance and  

secure with 2 screws. 

j.  Refit the knobs to the gas control valve spindles. 

Stainless Steel Surfaces 

a.  Clean the exterior surfaces of the barbeque 

with hot water, a mild detergent solution and 

a soft scrubbing brush.  Note that the gas 
control knobs are a push fit onto the gas  
control valve spindles and can be removed 
to allow cleaning of the front control panel. 

b.  Baked on deposits or discolouration may  

require a good quality stainless steel cleaner 
or stainless steel wool.  Always apply cleaner 
when the appliance is cold and rub in the 
direction of the grain. 

c.  To remove any discolouration, use an  

approved stainless steel cleaner or stainless 
steel wool.  Always rub in the direction of the 
grain. 

d.  Remove the grease tray and clean with a 

mild anti bacterial detergent and hot water 
solution using a soft bristled brush. 

e.  Dry the grease tray thoroughly with a dry 

cloth. 

f.  Dry all components thoroughly with a dry 

cloth and polish with a soft dry cloth. 

 

Two Screws 

Spindle 

Содержание CB6

Страница 1: ...Gas Barbeque Models CB6 600mm CB9 900mm I N S T A L LA T I ON A N D OP E R A T I ON M A N U A L 242355 1 ...

Страница 2: ...ervice tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales tel 44 121 327 5575 fax 44 121 32...

Страница 3: ...Installation Requirements Unpacking Assembly Location Clearances Gas Connection Commissioning Operation Guide Description of Controls Lighting the Pilot Burner Lighting the Main Burner General After Each Use Daily Cleaning Weekly Cleaning Periodic Maintenance Gas Conversion Procedure Gas Specifications ...

Страница 4: ...uctions for adapting the appliance to the conditions for use in that country IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOC...

Страница 5: ...to Gas Conversion Section in this manual for further details Natural Gas LP Gas Propane CB6 CB9 CB6 CB9 Input Rating 66 0 MJ hr 100 0 MJ hr 66 0 MJ hr 100 0 MJ hr Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 0 95 kPa 2 60 kPa Gas Connection BSPT Male BSPT Male BSPT Male BSPT Male Propane G31 CB6 CB9 CB6 CB9 Heat Input nett Nominal 18 0 kW 27 kW 18 0 kW 27 kW Reduced 6 0 kW...

Страница 6: ...ly 215mm from the left hand side and 535mm from the floor and is entered from beneath the appliance Gas Connection is BSPT male For CB9 Approximately 215mm from the left hand side and 555mm from the floor and is entered from beneath the appliance Gas Connection is BSPT male LP Gas Propane LP Gas Butane CB6 CB9 CB6 CB9 Input Rating 66 0 MJ hr 100 0 MJ hr 66 0 MJ hr 100 0 MJ hr Supply Pressure 2 75 ...

Страница 7: ...5 ...

Страница 8: ...6 ...

Страница 9: ...sit protection from the appliance including all protective plastic coating from the door outer panel and exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to the carrier and distributor Report any deficiencies to the distributor who supplied the appliance Check that the available gas supply is correct to that shown on the rating plate attached to th...

Страница 10: ...d stickers located above the gas entry point and next to the rating plate Check that this is correct for the gas supply the appliance is being installed for The gas conversion procedure is detailed in the Gas Conversion Instruction Sheet for this appliance b Supply Pressure required for this appliance is shown in the Specifications section of this manual Check the gas supply to ensure that adequat...

Страница 11: ...s correctly and the operator s understand the correct operating procedure 1 Before leaving the new installation a Check the following functions in accordance with the operating instructions specified in the Operation section of this manual Light the Pilot Burners Light the Main Burners Check the Low Fire Burner Operation Check the High Fire Burner Operation b Ensure that the operator has been inst...

Страница 12: ...he desired heat 4 During idle periods the main burners can be turned down to maintain an appropriate plate temperature or the gas controls can be set to the PILOT position as required NOTE Always set the gas control knob to the HIGH position when lighting the main burners If the pilot burner goes out during normal operation wait 5 minutes before attempting to re light the pilot burner 1 The Cobra ...

Страница 13: ...the burners are fitted correctly over the main injectors and are located properly into the recesses in the barbeque Clean the Barbeque regularly A clean barbeque looks better will last longer and will perform better Carbonised grease on the surface or on the barbeque will hinder the transfer of heat from the cooking surface to the food This will result in loss of cooking efficiency NOTE DO NOT use...

Страница 14: ...r pull out gas control spindle again noting its orientation g Apply a suitable high temperature gas cock grease or lubricant such as ROCOL A S P Anti scuffing paste Dry Moly Paste to the outside of spindle h Replace spindle and re assemble the gas control in reverse order i Refit the control panel to the appliance and secure with 2 screws j Refit the knobs to the gas control valve spindles Stainle...

Страница 15: ... service provider Call service provider This section provides an easy reference guide to the more common problems that may occur during operation of your equipment The fault finding guide in this section is intended to help you correct or at least accurately diagnose problems with your equipment Although this section covers the most common problems reported you may encounter a problem not covered ...

Страница 16: ...er as shown in Gas Specifications Tables at rear of this section 4 Refit the following Main burners Inner radiants chargrill castings griddle plates 1 Disconnect the following Gas supply tube to pilot burner 2 Remove pilot injectors and replace with correct size pilot injectors as shown in Gas Specifications Tables at rear of this section 3 Re connect the following Gas supply tube to pilot burner ...

Страница 17: ...ns correct Re adjust the regulator if required 5 Screw the cap nut back onto the regulator NOTE Pin rotated for Natural Gas NOTE Pin rotated for LPG Pressure Adjusting Screw Cap Nut On completion of the gas conversion replace gas type labels located at The rear of the unit above gas connection Beside the rating plate Before leaving the converted installation 1 Check all gas connections for leakage...

Страница 18: ... 40 kPa 2 75 4 50 kPa Burner Operating Pressure 0 95 kPa 2 6 kPa Main Burner Aeration Shutter Fully Open Fully Open Gas Regulator Cap Screw Main Burner Injectors 2 70 mm 1 65 mm Pilot Burner Injectors 0 45 0 30 Low Fire Adjustment 11 4 turns out ccw turn out ccw Supply Pressure 20 mbar 30 37 mbar Burner Operating Pressure 10 mbar 26 mbar Main Burner Aeration Shutter Fully Open Fully Open Gas Regul...

Страница 19: ...nd Specifications section of this manual for further details Main Burner Injectors 2 70mm 4 50mm Pilot Burner Injectors 0 45 0 75 Low Fire Adjustment 11 4 turns out ccw 2 turns out ccw Burner Operating Pressure 0 95 kPa 0 63 kPa Main Burner Aeration Shutter Fully Open Fully Open Gas Regulator Cap Screw Adjustable Regulator Adjust to the Burner Operating Pressure specified Main Burner Injectors 1 6...

Страница 20: ... Pilot Orifice Town Gas 0 75 019624 Ignition HT Electrode 229731 Ignition HT Lead 250mm General 229870 Burner Radiant Casting 229869 Top Grate Casting 242306 Drip Tray CB6 242307 Drip Tray CB9 242352 Leg Assembly 150mm c w Leg Plate 229674 Rear Roller Assy Regulators Gas Conversion Kits IMPORTANT Only genuine qualified replacement parts should be used for the servicing and repair of this appliance...

Страница 21: ......

Отзывы: