Cobra CB6 Скачать руководство пользователя страница 10

1.  Installation must allow for a sufficient flow of fresh 

air for the combustion air supply. 

2.  This appliance must be installed in a suitably  

ventilated room to prevent dangerous build up 
of combustion products. 

3.  Position the appliance in its approximate 

working position. 

4.  All air for burner combustion is supplied from 

underneath the appliance.  The legs must 
always be fitted and no obstructions placed on 
the underside or around the base of the 
appliance, as obstructions will cause incorrect 
operation and / or failure of the appliance. 

5.  Components having adjustments protected 

(e.g. paint sealed) by manufacturer are only to 
be adjusted by an qualified service agent.  They 
are not to be adjusted by the installation person. 

 

NOTE: 
Do not obstruct or block the appliances flue.  Never 
directly  connect  a  ventilation  system  to  the  
appliance flue outlet. 

 

 

NOTE: 
Only  non-combustible  materials  can  be  used  in 
close proximity to this appliance. 
 

Any gas burning appliance requires adequate 
clearance and ventilation for optimum and trouble-
free operation.  The following minimum installation 
clearances are to be adhered to: 

 

LH / RH 

Side 

200mm 

0mm 

Rear 

100mm 

0mm 

NOTE: 
ALL  GAS  FITTING  MUST  ONLY  BE  CARRIED  OUT  BY  A 
QUALIFIED SERVICE PERSON. 

 
1.  Cobra Model Barbeques do not require an 

electrical connection, they function totally on 
the gas supply only. 

2.  It is essential that the gas supply is correct for the 

appliance being installed and that adequate 
supply pressure and volume are available.  The 
following checks should be made before 
installation is commenced:- 
a. 

The Gas Type 

the appliance has been  

supplied for is shown on coloured stickers  
located above the gas entry point and next 

to the rating plate.  Check that this is correct 
for the gas supply the appliance is being  
installed for.  The gas conversion procedure is 
detailed in the ‘Gas Conversion Instruction 
Sheet' for this appliance. 

b. 

Supply Pressure 

required for this appliance is 

shown in the “Specifications” section of this 
manual.  Check the gas supply to ensure that 
adequate supply pressure exists. 

c. 

Input Rate 

of this appliance is also stated on 

the rating plate attached to the inner R/H 
side, below the grease tray, and in the 
“Specifications” section of this manual.  The 
input rate should be checked against the 
available gas supply line capacity.  

Particular 

note should be taken if the appliance is  
being added to an existing installation.

 

 

NOTE: 
It  is  important  that  adequately  sized  piping  runs 
directly  to  the  connection  joint  on  the  appliance, 
with  as  few  tees  and  elbows  as  possible  to  give 
maximum supply volume. 

 

3.  Fit the gas regulator supplied, into the gas supply 

line as close to the appliance as possible. 

The regulator connections are 

½

" BSPT female. 

The connection is 

½

" BSPT male. 

(Refer to the ‘Specifications’ section for the 
gas supply location dimensions). 

 

NOTE: 
The  gas  pressure  regulator  provided  with  this  

appliance  is  convertible  between  Natural  Gas  and 
LPG  as  per  the  ‘Gas  Conversion  Section’  in  this  
manual. 

 

Ensure the regulator is converted to the correct gas 
type that the appliance will operate on. 
The  regulator  outlet  pressure  is  fixed  ex-factory  for 
the gas type that the regulator is converted to and it 

is NOT to be adjusted. 
 

4.  A suitable joining compound which resists the 

breakdown action of LPG must be used on 
every gas line connection, unless compression 
fittings are used. 

Combustion Air Requirements (Minimum) 

 

CB6 

CB9 

Natural Gas

 

18 m³/hr  

27 m³/hr  

LPG / Propane

 

18 m³/hr  

27 m³/hr  

Содержание CB6

Страница 1: ...Gas Barbeque Models CB6 600mm CB9 900mm I N S T A L LA T I ON A N D OP E R A T I ON M A N U A L 242355 1 ...

Страница 2: ...ervice tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1455 Toll Free NEW ZEALAND Moffat Limited Web www moffat co nz E Mail sales moffat co nz Main Office tel 0800 663328 UNITED KINGDOM Blue Seal Web www blue seal co uk E Mail sales blue seal co uk Sales tel 44 121 327 5575 fax 44 121 32...

Страница 3: ...Installation Requirements Unpacking Assembly Location Clearances Gas Connection Commissioning Operation Guide Description of Controls Lighting the Pilot Burner Lighting the Main Burner General After Each Use Daily Cleaning Weekly Cleaning Periodic Maintenance Gas Conversion Procedure Gas Specifications ...

Страница 4: ...uctions for adapting the appliance to the conditions for use in that country IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT LOC...

Страница 5: ...to Gas Conversion Section in this manual for further details Natural Gas LP Gas Propane CB6 CB9 CB6 CB9 Input Rating 66 0 MJ hr 100 0 MJ hr 66 0 MJ hr 100 0 MJ hr Supply Pressure 1 13 3 40 kPa 2 75 4 50 kPa Burner Operating Pressure 0 95 kPa 2 60 kPa Gas Connection BSPT Male BSPT Male BSPT Male BSPT Male Propane G31 CB6 CB9 CB6 CB9 Heat Input nett Nominal 18 0 kW 27 kW 18 0 kW 27 kW Reduced 6 0 kW...

Страница 6: ...ly 215mm from the left hand side and 535mm from the floor and is entered from beneath the appliance Gas Connection is BSPT male For CB9 Approximately 215mm from the left hand side and 555mm from the floor and is entered from beneath the appliance Gas Connection is BSPT male LP Gas Propane LP Gas Butane CB6 CB9 CB6 CB9 Input Rating 66 0 MJ hr 100 0 MJ hr 66 0 MJ hr 100 0 MJ hr Supply Pressure 2 75 ...

Страница 7: ...5 ...

Страница 8: ...6 ...

Страница 9: ...sit protection from the appliance including all protective plastic coating from the door outer panel and exterior stainless steel panels Check equipment and parts for damage Report any damage immediately to the carrier and distributor Report any deficiencies to the distributor who supplied the appliance Check that the available gas supply is correct to that shown on the rating plate attached to th...

Страница 10: ...d stickers located above the gas entry point and next to the rating plate Check that this is correct for the gas supply the appliance is being installed for The gas conversion procedure is detailed in the Gas Conversion Instruction Sheet for this appliance b Supply Pressure required for this appliance is shown in the Specifications section of this manual Check the gas supply to ensure that adequat...

Страница 11: ...s correctly and the operator s understand the correct operating procedure 1 Before leaving the new installation a Check the following functions in accordance with the operating instructions specified in the Operation section of this manual Light the Pilot Burners Light the Main Burners Check the Low Fire Burner Operation Check the High Fire Burner Operation b Ensure that the operator has been inst...

Страница 12: ...he desired heat 4 During idle periods the main burners can be turned down to maintain an appropriate plate temperature or the gas controls can be set to the PILOT position as required NOTE Always set the gas control knob to the HIGH position when lighting the main burners If the pilot burner goes out during normal operation wait 5 minutes before attempting to re light the pilot burner 1 The Cobra ...

Страница 13: ...the burners are fitted correctly over the main injectors and are located properly into the recesses in the barbeque Clean the Barbeque regularly A clean barbeque looks better will last longer and will perform better Carbonised grease on the surface or on the barbeque will hinder the transfer of heat from the cooking surface to the food This will result in loss of cooking efficiency NOTE DO NOT use...

Страница 14: ...r pull out gas control spindle again noting its orientation g Apply a suitable high temperature gas cock grease or lubricant such as ROCOL A S P Anti scuffing paste Dry Moly Paste to the outside of spindle h Replace spindle and re assemble the gas control in reverse order i Refit the control panel to the appliance and secure with 2 screws j Refit the knobs to the gas control valve spindles Stainle...

Страница 15: ... service provider Call service provider This section provides an easy reference guide to the more common problems that may occur during operation of your equipment The fault finding guide in this section is intended to help you correct or at least accurately diagnose problems with your equipment Although this section covers the most common problems reported you may encounter a problem not covered ...

Страница 16: ...er as shown in Gas Specifications Tables at rear of this section 4 Refit the following Main burners Inner radiants chargrill castings griddle plates 1 Disconnect the following Gas supply tube to pilot burner 2 Remove pilot injectors and replace with correct size pilot injectors as shown in Gas Specifications Tables at rear of this section 3 Re connect the following Gas supply tube to pilot burner ...

Страница 17: ...ns correct Re adjust the regulator if required 5 Screw the cap nut back onto the regulator NOTE Pin rotated for Natural Gas NOTE Pin rotated for LPG Pressure Adjusting Screw Cap Nut On completion of the gas conversion replace gas type labels located at The rear of the unit above gas connection Beside the rating plate Before leaving the converted installation 1 Check all gas connections for leakage...

Страница 18: ... 40 kPa 2 75 4 50 kPa Burner Operating Pressure 0 95 kPa 2 6 kPa Main Burner Aeration Shutter Fully Open Fully Open Gas Regulator Cap Screw Main Burner Injectors 2 70 mm 1 65 mm Pilot Burner Injectors 0 45 0 30 Low Fire Adjustment 11 4 turns out ccw turn out ccw Supply Pressure 20 mbar 30 37 mbar Burner Operating Pressure 10 mbar 26 mbar Main Burner Aeration Shutter Fully Open Fully Open Gas Regul...

Страница 19: ...nd Specifications section of this manual for further details Main Burner Injectors 2 70mm 4 50mm Pilot Burner Injectors 0 45 0 75 Low Fire Adjustment 11 4 turns out ccw 2 turns out ccw Burner Operating Pressure 0 95 kPa 0 63 kPa Main Burner Aeration Shutter Fully Open Fully Open Gas Regulator Cap Screw Adjustable Regulator Adjust to the Burner Operating Pressure specified Main Burner Injectors 1 6...

Страница 20: ... Pilot Orifice Town Gas 0 75 019624 Ignition HT Electrode 229731 Ignition HT Lead 250mm General 229870 Burner Radiant Casting 229869 Top Grate Casting 242306 Drip Tray CB6 242307 Drip Tray CB9 242352 Leg Assembly 150mm c w Leg Plate 229674 Rear Roller Assy Regulators Gas Conversion Kits IMPORTANT Only genuine qualified replacement parts should be used for the servicing and repair of this appliance...

Страница 21: ......