Appendix A: Gas Type Conversion
Revision 2
©
Moffat Ltd, August 2012
Cobra Series Gas Barbeque
Gas Specifications
- Non UK Only:
- UK Only:
(*) NOTE:
The burner operating pressure is to be measured at the manifold test point with two
burners operating at the 'High Flame' setting.
NAT, LPG & Butane Only - The operating pressure is ex-factory set and is not to be
adjusted, apart from when converting between gasses, if required.
TOWN GAS Only - The burner operating pressure is to be adjusted using the adjustable
gas regulator supplied.
Refer to the ‘Gas Conversion and Specifications' section of this manual for further details.
Natural Gas
LP Gas
(Propane)
Butane
Town Gas
Main Burner Injectors
2.70mm
1.65mm
1.55mm
4.50mm
Pilot Burner Injectors
0.45
0.30
0.30
0.75
Low Fire Adjustment
1
1
/
4
turns out (ccw) ½ turn out (ccw) ½ turn out (ccw) 2 turns out (ccw)
Operating Pressure
0.95 kPa (*)
2.6 kPa (*)
2.6 kPa (*)
0.63 kPa (*)
Main Burner Aeration
Shutter
Fully Open
Fully Open
Fully Open
Fully Open
Gas Regulator Cap
Screw
Adjustable
Regulator
(Adjust to the
Burner Operating
Pressure
specified)
Natural Gas
(G20)
Propane
(G31)
Main Burner Injectors
2.70mm
1.65mm
Pilot Burner Injectors
0.45
0.30
Low Fire Adjustment
1
1
/
4
turns out (ccw)
½ turn out (ccw)
Operating Pressure
10 mbar (*)
26 mbar (*)
Main Burner Aeration
Shutter
Fully Open
Fully Open
Gas Regulator Cap
Screw