100-M0105X1
12
of
23
www.cobham.com/gms
Figure 4 Chaining Out TX to Chaining In VNA
Figure
5
Chaining Out VR to Chaining In VNA
Use individual screened cables (type RG 174 or better) for each signal and connect each screen to the
corresponding ground pin as shown in
Figure 6 (RX example). The lengths of the cables should be matched and they should not exceed 20cm
in length for reliable system operation.
Figure 6 VNA Connectors Layout
14
15
13
10
11
9
13
12
11
VNA
TX
J8
J1
14
15
13
10
11
9
13
12
11
VNA
RX
J11
J1
RX
J11
VNA
J5