Alerts and notifications
50
Chapter 2: Operation
98-135323-H
If the connection between the SAILOR 6282 AIS Transponder and the SAILOR
6004 Control Panel is lost, the SAILOR 6004 Control Panel shows an error
“Connection lost”. The reason may be that someone is connected to the SAILOR
6282 AIS Transponder using the Service Interface.
3119/35
C
B
Missing
ROT
Not transmitting
Rate of Turn
Check the NMEA connection
between ROT sensor and AIS
transceiver; check the GNSS
antenna, plugs, and cable to
the AIS transceiver; check the
NMEA connection between
the external GNSS receiver
and the AIS Transponder.
3079/51
C
B
TX Silent
Active
TX Silent Mode
Active
The alert is cleared when
the
Silent Mode
is
deselected.
3078/52
W
B
DIM Are
Not Set
Dimensions are
not set
Position source reference
point is not set.
The alarm is cleared when
the ship dimensions
(A,B,C,D) are not all set to
zero. The values can e.g.
be set in the Service
Interface.
3009/53
C
B
EPV reboot EPV received,
AIS will reboot
in 200 sec.
Notification that the AIS will
reboot, no action required,
alert is cleared after reboot
ID/
Instance
Prio-
rity
Cate-
gory
Title
Description
Reasons and remedy
Содержание SAILOR 6280
Страница 1: ...SAILOR 6282 AIS Transponder SAILOR 6280 6281 AIS System User manual...
Страница 2: ......
Страница 12: ...Table of contents x 98 135323 H...
Страница 74: ...Service and repair 62 Chapter 3 Service maintenance 98 135323 H...
Страница 82: ...Sentences defined by Cobham SATCOM 70 Appendix B NMEA sentences 98 135323 H...
Страница 90: ...98 135323 H www cobhamsatcom com...