background image

BBG-1300-OM  (V1.0)

BBG-1300-FR PRODUCT MANUAL

1-9

Introduction

Warranty and Service Information

Warranty and Service Information

Cobalt Digital Inc. Limited Warranty

This product is warranted to be free from defects in material and workmanship for a period of five (5) 
years from the date of shipment to the original purchaser, except that 4000, 5000, 6000, 8000 series 
power supplies, and Dolby

®

 modules (where applicable) are warranted to be free from defects in 

material and workmanship for a period of one (1) year.

Cobalt Digital Inc.'s (“Cobalt”) sole obligation under this warranty shall be limited to, at its option, (i) 
the repair or (ii) replacement of the product, and the determination of whether a defect is covered under 
this limited warranty shall be made at the sole discretion of Cobalt.

This limited warranty applies only to the original end-purchaser of the product, and is not assignable or 
transferrable therefrom. This warranty is limited to defects in material and workmanship, and shall not 
apply to acts of God, accidents, or negligence on behalf of the purchaser, and shall be voided upon the 
misuse, abuse, alteration, or modification of the product. Only Cobalt authorized factory 
representatives are authorized to make repairs to the product, and any unauthorized attempt to repair 
this product shall immediately void the warranty. Please contact Cobalt Technical Support for more 
information.

To facilitate the resolution of warranty related issues, Cobalt recommends registering the product by 
completing and returning a product registration form. In the event of a warrantable defect, the 
purchaser shall notify Cobalt with a description of the problem, and Cobalt shall provide the purchaser 
with a Return Material Authorization (“RMA”). For return, defective products should be double boxed, 
and sufficiently protected, in the original packaging, or equivalent, and shipped to the Cobalt Factory 
Service Center, postage prepaid and insured for the purchase price. The purchaser should include the 
RMA number, description of the problem encountered, date purchased, name of dealer purchased 
from, and serial number with the shipment.

Cobalt Digital Inc. Factory Service Center
2506 Galen Drive

Office: (217) 344-1243

Champaign, IL 61821 USA

Fax:

(217) 344-1245

www.cobaltdigital.com

Email: [email protected]

THIS LIMITED WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES 
EXPRESSED OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE AND OF ALL OTHER OBLIGATIONS OR 
LIABILITIES ON COBALT'S PART. ANY SOFTWARE PROVIDED WITH, OR FOR USE WITH, 
THE PRODUCT IS PROVIDED “AS IS.” THE BUYER OF THE PRODUCT ACKNOWLEDGES 
THAT NO OTHER REPRESENTATIONS WERE MADE OR RELIED UPON WITH RESPECT TO 
THE QUALITY AND FUNCTION OF THE GOODS HEREIN SOLD. COBALT PRODUCTS ARE 
NOT AUTHORIZED FOR USE IN LIFE SUPPORT APPLICATIONS.

COBALT'S LIABILITY, WHETHER IN CONTRACT, TORT, WARRANTY, OR OTHERWISE, IS 
LIMITED TO THE REPAIR OR REPLACEMENT, AT ITS OPTION, OF ANY DEFECTIVE 
PRODUCT, AND SHALL IN NO EVENT INCLUDE SPECIAL, INDIRECT, INCIDENTAL, OR 
CONSEQUENTIAL DAMAGES (INCLUDING LOST PROFITS), EVEN IF IT HAS BEEN 
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. 

Содержание BBG-1300-FR

Страница 1: ...506 Galen Drive Champaign IL 61821 Voice 217 344 1243 Fax 217 344 1245 www cobaltdigital com Product Manual BBG 1300 OM V1 0 Cobalt Digital Inc 1RU Enclosure for openGear Cards BBG 1300 FR BBG 1300 FR...

Страница 2: ...n or design Cobalt Digital Inc does not assume any liability arising out of the application or use of any product or circuit described herein Trademark Information Cobalt is a registered trademark of...

Страница 3: ...rvicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as when the power supply cord or plug is damaged liquid has been spilled or objects hav...

Страница 4: ...tial area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense Changes or modifications to this equipment not expressly approve...

Страница 5: ...ifications 1 8 Warranty and Service Information 1 9 Cobalt Digital Inc Limited Warranty 1 9 Contact Cobalt Digital Inc 1 10 Chapter 2 Installation and Setup 2 1 Overview 2 1 Installing the BBG 1300 FR...

Страница 6: ...nnection 2 14 BBG 1300 FR DashBoard Status and Expanded Network Settings Interfaces 2 17 BBG 1300 FR Info Tabs 2 17 BBG 1300 FR Setup Network and Auxiliary Function Control Tabs 2 19 Setting Configuri...

Страница 7: ...pter contains the following information Manual Conventions p 1 1 Safety Summary p 1 3 BBG 1300 FR Functional Description p 1 3 Technical Specifications p 1 8 Warranty and Service Information p 1 9 Con...

Страница 8: ...plemental information to the accompanying text Notes typically precede the text to which they apply Labeling Symbol Definitions Important note regarding product usage Failure to observe may result in...

Страница 9: ...th a total available power of 60 W Up to three BBG 1300 FR units can fit onto a single 1RU tray for maximum density where a 2RU frame is not feasible The BBG 1300 FR allows Ethernet connectivity to an...

Страница 10: ...BBG 1300 FR Front View with Card Access Front Door Separated from Chassis Figure 1 2 BBG 1300 FR Rear View Card User Slot Area 2 Slots max Looping Reference Connectors Network Ethernet Connector Redun...

Страница 11: ...O Module that best suits the requirements The required input and outputs are broken out to the industry standard connectors on the module The BBG 1300 FR supports a Standard Width rear module which se...

Страница 12: ...osure This simplifies the setup and use of numerous modules in a large installation and offers the ability to centralize monitoring Cards define their controllable parameters to DashBoard so the contr...

Страница 13: ...ol Interface Computer with NIC OGCP 9000 Control Panel OGCP 9000 CC Control Panel and or WinOGCP Virtual Control Panel s BBG 1300 FR LAN Remote Control Panel Using the Control Panel cards are remotely...

Страница 14: ...ting or storage 32 104 F 0 40 C 95 non condensing Total available card net power 60 W One 1 card not exceeding 60 W or two 2 cards not exceeding 60 W total Available user card slots 2 maximum Note 2 c...

Страница 15: ...ering the product by completing and returning a product registration form In the event of a warrantable defect the purchaser shall notify Cobalt with a description of the problem and Cobalt shall prov...

Страница 16: ...h and professional support representatives for any of the following Name and address of your local dealer Product information and pricing Technical support Upcoming trade show information Phone 217 34...

Страница 17: ...g plate or regular table or desk surface without optional frame Mounting Tray BBG 1300 TRAY affix four adhesive backed rubber feet supplied to the bottom of BBG 1300 FR in locations marked with stampe...

Страница 18: ...tion dimensional details for the BBG 1300 FR 1 From front of tray slide unit into tray aligning with tray edge and or guides 2 Slide unit rear fully to rear of tray Secure unit to tray using captive f...

Страница 19: ...t through vents on all sides of the front bezel and via vents near the rear of the chassis Make certain these vents are not obstructed The BBG 1300 FR bottom has elastic type pads that help ensure tha...

Страница 20: ...ts Note For non redundant AC power input either receptacle can be used for power connection For redundant AC power inputs connect both receptacles to separate independent power sources 1 Connect suppl...

Страница 21: ...nnectors can receive ref input on either connector of the looping pair Unless daisy chained to another node an open connector here must be terminated into an appropriate 75 terminator Installing Rear...

Страница 22: ...While firmly holding BBG 1300 FR chassis with one hand grasp front bezel assembly and pull front bezel assembly straight away from chassis Align and engage mounting tab on Rear I O Module with the mo...

Страница 23: ...ngaging in Rear I O Module mating connector check for alignment and proper insertion in slot tracks Damage to card and or Rear I O Module may occur if improper card insertion is attempted 6 Repeat ste...

Страница 24: ...d one card is inserted in top guide pair and the other is inserted in lower guide pair 1 Card Edge Mating Connector Push card lightly and fully into slot until card edge connector on card fully mates...

Страница 25: ...available main menu items as well as sub menus when a main item is selected In some modes the menu displays system parametric data such as voltage and temperature data Soft Keys allow selection of men...

Страница 26: ...vice name in this example Frame has green background In cases where an alert alarm are present for the selected device the background appears as yellow or red Time based temperature graph plots of the...

Страница 27: ...basic network setup must be performed first as outlined in this section Once the BBG 1300 FR has a network connection established and is accessible using DashBoard remote control additional network an...

Страница 28: ...before pro ceeding to the next device If devices are connected too rapidly with out considering this it may be difficult to correlate device instances in DashBoard and the DHCP assigned addresses wit...

Страница 29: ...key L1 to go to the Frame BBG 1300 FR setup menu 2 Press Navigate Select knob to select Network The Address Mode sub menu is now displayed 3 Press Navigate Select knob and select DHCP 4 With DHCP hig...

Страница 30: ...main menu appears press soft key L1 to go to the Frame BBG 1300 FR setup menu 2 Press Navigate Select knob to select Network The Address Mode sub menu is now displayed 3 Press Navigate Select knob and...

Страница 31: ...ob to select desired value Note Numeric settings such as address fields can be incremented or decremented by either rotating the Navigate Select knob CW or CCW or pressing soft key R1 to increment or...

Страница 32: ...13 Press the knob again to move cursor to the next field Rotate knob to select desired value 14 Repeat until all fields are set as desired When all fields are set press the Navigate Select knob again...

Страница 33: ...ork as a DashBoard instance BBG 1300 FR appears in the DashBoard Basic Tree View identically to that of a standard rack mounted frame In addition to the Network tab described in the sections below for...

Страница 34: ...s how many cards user slots 1 and 2 are currently installed and recognized by the device Cobalt Support Network Status shows whether or not the Cobalt Support VPN connection to the device is enabled H...

Страница 35: ...sult in loss of user settings such as network settings Identify BBG 1300 FR Button When pressed provides a command to connected BBG 1300 FR to conspicuously identify itself by causing the BBG 1300 FR...

Страница 36: ...tings when card is set for static IP address BBG 1300 FR Name field allows entry of custom BBG 1300 FR name NTP and DNS Server fields allow entry of NTP and DNS servers where used Address Mode shows c...

Страница 37: ...on cards hidden until enumerated similar to above but waits until cards are fully enumerated before displaying a card Note All known instances of Cobalt openGear cards support parameter caching If car...

Страница 38: ...o Ignore Off temporarily muted state alarm may be currently being issued but has been muted via the device menu or via DashBoard Mute Audible Alarm here Note If hardware Mute jumper is set to disable...

Страница 39: ...or GET requests Read write Community String accepts SNMP password for SET requests System Contact and System Location are auxiliary info fields that can be used to provide this info or can be disregar...

Страница 40: ...be temporarily muted To persistently mute the device alert beeper perform the following steps to access the MUTE jumper and set to Mute position 1 Remove the front bezel as shown in Figure 2 5 on pag...

Страница 41: ...ct knob displays device current firmware version Also displayed is the Cobalt Digital corporate mail address and local area telephone number Troubleshooting Troubleshooting Network Remote Control Erro...

Страница 42: ...out BBG 1300 FR and LAN computer on different networks Make certain LAN hosting computer and BBG 1300 FR are on same network Address conflict with other nodes or another Network Card Make certain that...

Страница 43: ...300 FR 2 Remove the front bezel as shown in Figure 2 5 on page 2 7 3 Power up the BBG 1300 FR Note To access PCB buttons on next steps if possible place the BBG 1300 FR on its left side This will make...

Страница 44: ...as specific shipping instructions If required a temporary replacement item will be made available at a nominal charge Any shipping costs incurred are the customer s responsibility All products shippe...

Страница 45: ......

Страница 46: ...Cobalt Digital Inc 2605 Galen Drive Champaign IL 61821 Voice 217 344 1243 Fax 217 344 1245 www cobaltdigital com BBG 1300 OM V1 0 Printed in USA...

Отзывы: