3
BBG-1022-FS Function Menu List and Descriptions
3-70
BBG-1022-FS PRODUCT MANUAL
BBG1022FS-OM (V1.4)
(continued)
Table 3-1
BBG-1022-FS Function Menu List — continued
Audio sub-tabs independently show for all 16 embedded channels any missing audio (whether absent due to low
level, mute or unlocked status).
Note: Audio screened is the audio associated with the selected card SDI program inputs.
Independent rows are present for each of the program path 16 embedded audio channels. Log, Alarm, Severity and Duration/
Last Occurrence controls and status function as described in Video (p. 3-69).
Unused audio channels should, at the minimum, have Severity set to Ignore/OK. If this is
not done, nuisance alarms may occur.
Ancillary Data sub-tab shows loss of closed captioning packet presence for program video path.
Note: • Closed captioning screened are the CC packet presence associated with the selected card SDI
program inputs.
• Ancillary data condition detection is functional only for CEA608/708 packet-based closed
captioning. This feature does not function for SD line 21 “waveform-based” closed captioning.
Independent rows are present for both program paths. Log, Alarm, Severity and Duration/Last Occurrence controls and status
function as described in Video (p. 3-69).