Page 9
Logic board switch settings continued:
SW2
Poles
1
2
3 Nominal
%
Payout
0 0 0
30
1 0 0
35
0 1 0
40
1
1
0
45 (Factor Setting)
0 0 1
50
1 0 1
55
0 1 1
60
1 1 1
65
SW2 Pole 4
Pole 4 is used to ‘reset ‘ the current payout percentage registers. When in play, the program
tracks the payouts and adjusts the availability of the higher value cards so as to maintain the
selected percentage payout (poles 1-3).
When the percentage settings are altered, it may be desired to reset the program to the new
settings immediately, rather than allowing the program to adjust over a period of time. This
‘register reset’ may be achieved by selecting pole 4 to ON, switching the machine ON, and
then switching pole 4 OFF. In confirmation of the register reset, a ‘coin-in’ sound will be
generated.
It is a feature of the electronics that data regarding game play is written to a non-volatile
RAM. As such the machine ‘remembers’ unpaid awards etc. These events can’t therefore,
be cleared by switching off then on again, they must occur in order to be released from a
‘call attendant’ mode. The red beacon light illuminates over the section when such a
situation occurs.
Bonus Empty Caption – Coin Entry Door
Should the supply of tickets run out, the ‘
Bonus empty when light’
caption on the coin entry
door will illuminate continuously.