Start Up Instructions
FILLING YOUR TUBLICIOUS HOT TUB
Your new hot tub has left the factory cleaned and polished. You may have to clean out
any dirt that has accumulated during shipping. Use warm water and a sponge or cloth.
Be sure that all fittings are connected, secure and hand tightened in the equipment
area (Refer to picture on Page 24). Your TubLicious hot tub is shipped with fittings
disconnected to ensure no damage or freezing occurs during the hot tub’s route from
our factory to your home.
Fill your TubLicious hot tub with your garden hose. Place the hose inside the skimmer/
filter canister and secure the hose in place. Filling through the filter helps to allow most
of the trapped air in the pumps and heater to be eliminated. (Refer to Page 23)
Note: TubLicious recommends that you do not fill your hot tub with hot water.
Excessively hot water (over 107°F) may cause damage to components in the spa pack
as well as all plastic and acrylic components.
Also: Do not fill your hot tub with water from a water softener. If your water is
extremely hard your TubLicious dealer can help you to remedy this problem.
Continue filling the hot tub to half (3/4) way up the skimmer opening. Remove the
hose and close the filter canister. (See Filter Maintenance Section)
CONTROL PANEL
Please read the CONTROL PANELS Card (See pages 14-15) pertaining to the hot tub topside
control and control box supplied with your unit. This must be done before starting up your hot
tub to prevent any damage to the unit.
INITIAL START-UP OF PUMP
Turn power off at the breaker.
Ensure all union fittings are tightened (Refer to Page 24)
Turn power on at GFCI, mounted in cord. Turn on pump. If circulation is not visible,
turn off pump #1, open bleeder valve on top of pump and allow air to escape until wa-
ter comes out steadily. Re-tighten bleeder valve (finger tight only). Note: Bleeder valve
only needs to be loosened and not completely removed (Refer to Page 24). If there is
still no circulation, gently loosen the pump union until only water is present and no air.
Allow pump to circulate for 2-3 minutes before activating heater.
WARNING: RUNNING THE PUMPS WITH NO WATER CIRCULATING IN HOT TUB, COULD
DAMAGE THE PUMPS AND PUMP SEALS
7
Содержание TubLicious 2011
Страница 14: ...INITIAL START UP Control Panel TubLicious 14 ...
Страница 15: ...DIAGNOSTIC MESSAGES Control Panel TubLicious 15 ...
Страница 19: ...TubLicious Cover Tie Down Strap Installation 19 ...
Страница 20: ...TubLicious Cover Tie Down Strap Installation 20 ...
Страница 23: ...TubLicious Layout 23 ...
Страница 24: ...TubLicious Equipment Area 24 ...
Страница 25: ...TubLicious Standard Features 25 ...
Страница 26: ...TubLicious Filter Replacement 26 ...