background image

5

Insert provided flexible brush through the appliance 
front  and blanking plate to clean top of boiler flueway. 
Fig. 8.
Access to rear boiler flueway with flexible flue brush is
made through the firedoor opening and rear boiler 
access hole. Fig. 9.
Brush deposits into firebox and replace flue blanking 
plate.

c. Replace boiler plug by inserting plug so that the locking

lugs on the plug pass through the corresponding slots in
boiler back. Figs. 7 and 9.
Turn plug one quarter turn in a clockwise direction 
(marked CLOSED) to lock.

d. Replace front firebar and close firedoor.

CHIMNEY SWEEPING:

SWEEP AT LEAST ONCE

ANNUALLY. See Figs. 10a and 10b.

WARNING:

NEGLECT OF CHIMNEY SWEEPING CAN

LEAD TO DANGEROUS FUME EMISSION.
Use wire centred sweep brushes fitted with a guide-wheel
for most efficient chimney sweeping.
Where the chimney is believed to have served an open fire
installation, it is possible that the higher flue gas
temperatures from a closed appliance may loosen deposits
that were previously firmly adhered, with the consequent
risk of flue blockage. It is therefore recommended that the
chimney be swept a second time after one month of
regular use.

Top Flue Only

The chimney can only be swept via the removal of the flue
pipe access door (above the appliance).

Back Flue Only in Recess

The chimney is swept through the rear elbow cleaning door
and the soot can be removed through the appliance.
a. Open the firedoor and remove the front firebar and 

bottomgrate bars.

b. Remove the boiler cleaning plug (as described under 

Appliance Cleaning) and using a flexible flue brush of 
adequate length, clean the vertical flue pipe via the rear
boiler access hole.

c. Insert the chimney sweeping brush into the main flue or

chimney, through the soot cleaning door entry, or the 
flue pipe or through the appliances as applicable.
Ensure the deposits are separately collected, or fall into
the firebox for removal.

d. Replace the removed components in the reverse 

procedure of removal.

NOTE:

ALWAYS CLEAN THE APPLIANCE OUTLETS AND

FLUEWAYS AFTER SWEEPING THE CHIMNEY AND FLUE
PIPE.

Use a damp sponge or a proprietary brand of stove cleaner
to clean exterior of stove.

WARNING:

DO NOT CLEAN THE STOVE WHEN HOT.

With use, the inside face of the glass door may become
coated with dust and deposits. To clean the glass, allow it
to cool and then wipe with a damp cloth and polish with a
dry one

1. Always use a qualified service engineer when service

is required.

2. An inspection of both firedoor and ashpit door seals 

should be made every heating season and replaced if
necessary.

When not in use remove all fuel and ashes from the 
firebox. Leave the ashpit door spinwheel at an open 
setting to allow a constant stream of air to pass through 
the stove.

If the fire is not used when there is a danger of frost the
whole system should be drained.

WARNING:

NEVER LIGHT THE FIRE IF THE WATER 

SYSTEM IS FROZEN.

CLEANING

SERVICING

PRECAUTIONS

Содержание Much Wenlock Stove

Страница 1: ...examined before despatch IMPORTANT NOTICE Any alteration that is not approved by Aga Rayburn could invalidate the approval of the appliance operation of the warranty and could also affect your statutory rights Control of Substances Health and Safety Important This appliance may contain some of the materials that are indicated below It is the Users Installers responsibility to ensure that the neces...

Страница 2: ... CAN GIVE RISE TO ADVERSE OPERATING CONDITIONS FUELS SHOULD BE STORED UNDER COVER NOTE REFER PROBLEMS ABOUT FUEL SUITABILITY OR QUALITY TO FUEL SUPPLIER NOTE IT IS IMPORTANT THAT THE FUELS SHOULD BE OF THE CORRECT SIZE OTHERWISE THE APPLIANCE WILL NOT GIVE A SATISFACTORY PERFORMANCE WARNING DO NOT FIX AN EXTRACTOR FAN IN THE SAME ROOM AS THE APPLIANCE Sticks and Paper a Open the firedoor Fig 1 b L...

Страница 3: ...BY THE USE OF SMALLER SIZE FUEL e g SUNBRITE SINGLES The supply of hot water is dependent on the rate of burning and is greatest with the ashpit door spinwheel set at eight turns open and at least when the spinwheel is set at half turn open The boiler is designed to heat radiators as well as supply domestic hot water Fuel consumption will be higher when heating radiators and these should be turned...

Страница 4: ...ler flueways together with the flue pipe outlet should be swept on a monthly basis to prevent fly ash deposits restricting the flueway and prevent fume emission and reduced burning rates a Open the firedoor remove front firebar and prepare to remove the boiler cleaning plug located at the centre rear of firebox in front of boiler face Clear any deposits around the plug with a scraper then use a ha...

Страница 5: ... soot can be removed through the appliance a Open the firedoor and remove the front firebar and bottomgrate bars b Remove the boiler cleaning plug as described under Appliance Cleaning and using a flexible flue brush of adequate length clean the vertical flue pipe via the rear boiler access hole c Insert the chimney sweeping brush into the main flue or chimney through the soot cleaning door entry ...

Страница 6: ...5B MW212 HS5B MW213 HS1M 90295 HSFM 37539 JTHR 20389 JTHR 26389 Description Front firebar Bottomgrate upper Bottomgrate lower Ashpan Firedoor Glass Panel Firedoor Rope Seal 980mm length Ashpit Door Rope Seal 840mm length No Req 6 1 1 1 1 1 7 1 Set ...

Страница 7: ...7 ...

Страница 8: ...s policy of continuous product improvement the Company reserves the right to change specifications and make modifications to the appliance described and illustrated at any tim Manufactured By Aga Rayburn Station Road Ketley Telford Shropshire TF1 5AQ www aga rayburn co uk www agacookshop co uk ...

Отзывы: