Service manual
- 36 -
is set as low, the A/C operates at the DRY mode with a set temp. of 24
℃
9.11.3 All protections of remote control cooling are available at forced cooling operation
9.11.4 Forced Auto function
Select forced auto function with the forced auto button or the switch.
In forced auto status the A/C operates at remote control mode with a set temp. of 24
℃
Manual operation is controlled by touching buttons and divided into force cooling and forced auto mode.
It transfer between these two modes by pressing the buttons, the cycling order of the button press is as
below graph show to you.
Forced
cooling
Forced
auto
Remote
mode
9.12 Sleep mode(Economic mode)
9.12.1 The sleep function is available at cooling, heating or auto mode
9.12.2 Cooling:
The set temperature rise 1
℃
per hour. Two hours later, the set temperature will maintain as a
constant and the fan speed is kept at low speed.
Time
Room temperature
2
1
1'C
1'C
9.12.3 Heating:
The set temperature decrease 1
℃
per hour. Two hours later, the set temperature will maintain as
a constant and the air circulation is kept at low speed (Anti-cold function takes precedence over all).
Time
Room temperature
2
1
1'C
1'C