12
03
AC input voltage range
Appliances (default)
If selected, acceptable AC input
voltage range will be within
90-280VAC.
UPS
If selected, acceptable AC input
voltage range will be within
170-280VAC.
05
Battery type
AGM (default)
Flooded
User-Defined
If “User-Defined” is selected,
battery charge voltage can be set
up in program 26, 27.
06
Auto restart when overload
occurs
Restart disable (default)
Restart enable
07
Auto restart when over
temperature occurs
Restart disable (default)
Restart enable
09
Output frequency
50Hz (default)
60Hz
10
Output voltage
220V
230V (default)
240V
11
Maximum utility charging
current
Note: If setting value in
program 02 is smaller than
that in program in 11, the
inverter will apply charging
current from program 02 for
utility charger.
Default:30A
setting range is 2 A,10A to 80 A,
the increment or decrement is 10A
per click.
12
Setting voltage point back to
utility source when selecting
“SBU priority” or “Solar first”
in program 01.
Available options in 3.5KW model:
23.0V
(default)
Setting voltage point back
24V model:(default 23.0Vdc)
setting range :22.0V to 25.5V
setting increase or decrease of
0.5V.