vii.  After cleaning the quartz tube, wash it off with water and wipe 

dry with a soft towel.

viii.  Make sure the inside of the quartz tube is dry before installing 

the UV lamp. 

6E.  Quartz Tube Installation

i.  Place the sealing ring on the quartz tube 3/4 inch from the 

open end.

ii.  Insert the quartz tube partially into the UV chamber. Place the 

lamp retainer over the open end of the quartz tube and slowly 

push in until it is touching the UV chamber cap.

iii.  Place the retainer washers onto the retainer screws and tighten 

the lamp retainer screws until the lamp retainer is completely 

seated against the UV chamber cap.

iv.  After spa is refilled, turn the spa ON and check the seal around 

the lamp retainer for leaks.

v.  If the unit leaks, please contact customer support at following 

number: 1-800-733-9060.

vi.  SHUT DOWN the spa once you have confirmed that there are 

no leaks.

vii.  Install the UV lamp as described in Section 6B.

viii.  Reinstall the upper enclosure assembly to the enclosure base.

ix.  The unit is now ready for normal operation.

6F.  Standard Replacement Parts List

i.  Replacement UV Lamp Assembly 

 

9-1100-01

ii.  Quartz Tube Replacement Kit  

 

9-1204-01

iii.  Sealing 

Ring 

    7-1981-01

SECTION 2 Maintenance Instructions

Содержание DEL UV SPA

Страница 1: ...TY INFORMATION READ AND FOLLOW ALL INSTRUCTIONS Save these instructions Leave manual with homeowner after installation Improper installation adjustment alteration service or lack of maintenance can ca...

Страница 2: ...ed by a Ground Fault Circuit Interrupter G F C I If the DEL UV Spa is connected to an independent electrical supply then a G F C I must be installed between the DEL UV Spa and the electrical supply WA...

Страница 3: ...c UV Reactor Service Maintenance 7 d Quartz Tube Removal Cleaning 8 e Quartz Tube Installation 9 f Standard Replacement Parts List 9 SUPPORT 10 DIAGRAMS SHOWN IN THESE INSTRUCTIONS page 4 DEL UV SPA S...

Страница 4: ...plication other than a portable spa 2 Mounting a Use the two mounting holes located internally on the back panel of the DEL UV Spa Figure 1 b Mount the DEL UV Spa to the spa frame with 8 hardware The...

Страница 5: ...either direction Temporarily apply power to the spa and start the spa circulation system to check for and repair any water leaks Disconnect power to the spa Water Return to Spa Water from Spa Isolati...

Страница 6: ...ing the power cord parallel to any low voltage signal wires c Use a minimum 8 AWG solid copper conductor to connect the bonding lug provided on the enclosure base to the spa equipment ground 5 Operati...

Страница 7: ...HANDS Handle the lamp carefully and set aside If discarding dispose of properly see the following note NOTICE UV Lamp CONTAINS MERCURY Manage in accordance with disposal laws See www lamprecycle org 6...

Страница 8: ...he two retainer screws and retainer washer from the top of the lamp retainer and pull the lamp retainer out of the UV chamber cap NOTICE Any water remaining in the system above the level of the DEL UV...

Страница 9: ...and tighten the lamp retainer screws until the lamp retainer is completely seated against the UV chamber cap iv After spa is refilled turn the spa ON and check the seal around the lamp retainer for l...

Страница 10: ...__________________ System Purchased From _____________________________________________ Installation Date _____________________________ Serial Number _______________________________ Model Number ______...

Страница 11: ...11 NOTES...

Страница 12: ...CMP LLC 36 HERRING ROAD NEWNAN GA 30265 WWW C M P COM DEL 4 2769 01 Rev B_0921ab...

Отзывы: