AN201
Rev 1.5 | 23/91
www.cmostek.com
Notes
1.
CUS_LBD_RESULT register is a functional register, which is not not a parameter exported through the RFPDK, see Section
2.8 for details.
2.
The operating principle of LBD is: the chip compares the voltage value LBD_TH set by users (threshold of LBD) with the
actual voltage value LBD_RESULT got by the test; if LBD_RESULT is smaller than LBD_TH, it indicates the low voltage
occurs, on the contrary, it is the normal voltage. According to the comparison result, the LBD indicating signal will be output
internally. If LBD_OUT_EN is configured as 1, the LBD result will be sent out as part of the packet. See Section 2.7.1 for
details.
3.
In the chip, the voltage value is converted by a 4-bit ADC to obtain LBD_RESULT with each step as 0.2 V. The relationship
between the voltage value and LBD_RESULT is as follows.