CMNA DLFSHA Скачать руководство пользователя страница 7

32802000102                                                                                       Specifications subject to change without notice.                                                                                         

7

REMOTE CONTROL FUNCTIONS

Pressing ON/OFF

When the air conditioner is not in operation, the remote control
displays the last  set point and mode.

• Press 

ON/OFF

 to start the unit.

- The unit starts in the last operating mode and set point. The 

ON/OFF

 indicator appears.

• Press 

ON/OFF 

to stop the unit.

- All the indicator lights on the unit go out, and the remote 
control displays the set point and mode.

NOTE: If ON/OFF is pressed too soon after a stop, the 
compressor will not start for 3 to 4 minutes due to the 
inherent protection against frequent compressor cycling. 
The unit only emits an audible beep when the signals are 
received correctly.

Selecting an Operating Mode

Use 

OPERATING MODE

 to select one of the available modes.

Fig. 6 —Display

Setting the Room Temperature Set Point

Press the increase temperature set point   and decrease 

 buttons

to raise or lower the temperature.The unit confirms the signal receipt
with a beep and the value of the set temperature appears on the
display and changes accordingly. The temperature can be set
between 62°F (17°C) and 86°F (30°C) in increments of 1°F or 1°C.

NOTE: In the COOLING mode, if the temperature

selected is higher than the room temperature, the unit will

not start. The same applies for the HEATING mode if the

selected temperature is lower than the room temperature.

Selecting the Fan Speed

Fig. 7 —Fan Speeds

The fan speed can be selected by pressing 

FAN

.

NOTE: When the unit is on, the fan runs continuously in

cooling or heating. When in the HEATING mode, there

might be situations where the fan will slow down or shut

off to prevent cold blow.

Selecting the Up-Down Louver Position

To optimize comfort, the Up-Down louver operates in a preset range

(see Figure 8).

Fig. 8 —Louver Position

The up-down airflow louver can be adjusted and can be set to be
stationary or moving continuously pressing 

SWING 

. The Up-

Down louver position is stored in the settings, however it is

deactivated when the 

TURBO

 or 

MANUAL

 settings are set, or

when a power interruption takes place.

Air Direction

Press 

DIRECT

 repeatedly to choose one of the Up-Down louver

positions. Every time this button is pushed, the specific louver
swings by 6 degrees.
In the 

COOLING

DRY

, and 

FAN

 O

N

LY modes, the louver swings

in the cooling range. In the 

HEATING

 mode, the louver swings in

the heating range.

NOTE: Always use the remote control to adjust the Up-

Down louver position, otherwise abnormal operation may

occur. If the up-down louver is manually adjusted out of

its range, power the unit off and then back on again.

Auto Swing

For automatic Up-Down louver swing, push 

SWING 

.

Selecting Right-Left Direction of the Louver

The right-left louvers can be adjusted manually to direct the airflow
to achieve optimal comfort in the space.

Fig. 9 —Deflector Rod and Louver

 

COOLING

HEATING

Содержание DLFSHA

Страница 1: ...and keep this manual for future reference For your convenience please record the model and serial numbers of your new equipment in the spaces provided This information along with the installation dat...

Страница 2: ...user selected set point NOTE Auto mode is recommended for use on Single Zone applications only Using Auto changeover on multi zone applications could set an indoor unit to STANDBY mode indicated with...

Страница 3: ...r 3 seconds when TIMER ON is set SWING TURBO or SILENCE features are turned on TIMER OFF is set when defrosting when the anti cold air feature is turned on when the unit is self cleaning Display Code...

Страница 4: ...d down this button for 2 seconds to activate the GEAR function Starts and stops the louver movement Press this button the horizontal louver swings up and down automatically Hold down this button for 2...

Страница 5: ...when the unit is turned off TIMER ON display Battery display ECO display LOCK display Fan speed display Indicates that the LOCK function is on Displays selected fan speed Temperature Timer Fan speed d...

Страница 6: ...When transmitting a command from the remote control to the unit be sure to point the control toward the right side of the unit The unit confirms receipt of a command by sounding an audible beep 1 Tur...

Страница 7: ...cted temperature is lower than the room temperature Selecting the Fan Speed Fig 7 Fan Speeds The fan speed can be selected by pressing FAN NOTE When the unit is on the fan runs continuously in cooling...

Страница 8: ...e digital display on your remote control reverts to the temperature display The indicator remains on and this function is activated c Adjust the TIMER OFF settings to 0 0 to cancel this option Setting...

Страница 9: ...tivate the 46 F 8 C heating function heating set back The unit operates at a set temperature of 46 F 8 C The indoor unit display shows FP No icon will be displayed on the remote control NOTE This func...

Страница 10: ...until filter snaps in place 7 Close front panel on unit Fig 11 Filter Cleaning Indoor Unit Front Panel To clean the front panel on the indoor unit wipe the outside with a soft dry cloth Preparing for...

Страница 11: ...the display panel on the unit away from direct sunlight and heat as this may interfere with remote control transmissions Do not block air intakes and outlets on the indoor or outdoor units Energy Sav...

Страница 12: ...or units emit white mist When the unit restarts in HEAT mode after defrosting white mist may be emitted due to moisture generated from the defrosting process The indoor unit makes noises A rushing air...

Страница 13: ...structed Remove the obstruction The fan speed is too low Change the fan speed selection The operation mode is in Fan instead of Cool Change the operating mode to Cool or reset the unit Heating is Not...

Страница 14: ...Copyright 2018 CMNA 3300 Riverview Parkway Atlanta GA 30339 32802000102 Specifications subject to change without notice...

Отзывы: