Specifications subject to change without notice.                                                                         32802000102

A NOTE ABOUT SAFETY

Any time you see this symbol 

 in manuals, instructions and on the

unit, be aware of the potential for personal injury. There are three

levels of precaution:

DANGER

 identifies the most serious hazards which will result in

severe personal injury or death. 

WARNING

 signifies hazards that could result in personal injury or

death. 

CAUTION

 is used to identify unsafe practices which could result in

minor personal injury or product and property damage.
NOTE is used to highlight suggestions which will result in enhanced

installation, reliability, or operation.

GENERAL

The high wall fan coil unit provides quiet, maximum comfort. In

addition to cooling and/or heating, the high wall fan coil unit

matched with an outdoor condensing unit filters and dehumidifies

the air in the room to provide maximum comfort.

IMPORTANT:

 The high wall fan coil unit should be installed by

authorized personnel only; using approved tubing and accessories. If

technical assistance, service or repair is needed, contact the installer. 
The high wall fan coil unit can be set up and operated from the
remote control (provided). 

If the remote is misplaced, the system

can be operated from the “Auto” setting on the unit.

Operating Modes:

The high wall fan coil unit has five operating modes:

• FAN  Only
• AUTO 
• HEATING (heat pump models only)
• COOLING
• DEHUMIDIFICATION (DRY)

Fan Only

In the

 FAN Only 

mode, the system filters and circulates the room air

without changing room air temperature.

Auto

In the 

AUTO 

mode, the system automatically cools or heats the 

room according to the user-selected set point. mode, the system 
automatically cools or heats the room according to the user-selected 
set point.

NOTE: Auto mode is recommended for use on Single Zone
applications only. Using Auto changeover on multi-zone
applications could set an indoor unit to STANDBY mode,
indicated with two dashes (--) on the display, which will turn off
the indoor unit until all the indoor units are in the same mode
(Cooling or Heating). Heating is the system's priority mode.
Simultaneous Heating and Cooling is not allowed.

Heating

In the 

HEATING

 mode, the system heats and filters the room air.

Cooling

In the 

COOLING

 mode, the system cools, dries and filters the room air.

Dehumidification (DRY)

In the 

DEHUMIDIFICATION

 mode, the system dries, filters and

slightly cools the room air temperature. This mode prioritizes air
dehumidification but it does not take the place of a dehumidifier.

Wireless Remote Control

The remote control transmits commands to set up and operate the
system. The control has a window display panel that displays the
current system status. The control can be secured to a surface when
used with the mounting bracket provided.

Wired Remote Control (Optional)

Refer to the Wired Controller manual.

24V Interface (Optional)

Allows the control of the Ductless System with a third party thermostat.

PERSONAL INJURY, DEATH AND / OR PROPERTY 
DAMAGE HAZARD

Failure to follow this warning could result in personal injury,
death or property damage.
Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical
shock, or other conditions which may cause personal injury or
property damage. Consult a qualified installer, service
agency, or your distributor or branch for information or
assistance. The qualified installer or service agency must use
factory-authorized kits or accessories when modifying this
product.
Read and follow all instructions and warnings, including
labels shipped with or attached to unit before operating your
new air conditioner.

WARNING

Содержание DLFSHA

Страница 1: ...and keep this manual for future reference For your convenience please record the model and serial numbers of your new equipment in the spaces provided This information along with the installation dat...

Страница 2: ...user selected set point NOTE Auto mode is recommended for use on Single Zone applications only Using Auto changeover on multi zone applications could set an indoor unit to STANDBY mode indicated with...

Страница 3: ...r 3 seconds when TIMER ON is set SWING TURBO or SILENCE features are turned on TIMER OFF is set when defrosting when the anti cold air feature is turned on when the unit is self cleaning Display Code...

Страница 4: ...d down this button for 2 seconds to activate the GEAR function Starts and stops the louver movement Press this button the horizontal louver swings up and down automatically Hold down this button for 2...

Страница 5: ...when the unit is turned off TIMER ON display Battery display ECO display LOCK display Fan speed display Indicates that the LOCK function is on Displays selected fan speed Temperature Timer Fan speed d...

Страница 6: ...When transmitting a command from the remote control to the unit be sure to point the control toward the right side of the unit The unit confirms receipt of a command by sounding an audible beep 1 Tur...

Страница 7: ...cted temperature is lower than the room temperature Selecting the Fan Speed Fig 7 Fan Speeds The fan speed can be selected by pressing FAN NOTE When the unit is on the fan runs continuously in cooling...

Страница 8: ...e digital display on your remote control reverts to the temperature display The indicator remains on and this function is activated c Adjust the TIMER OFF settings to 0 0 to cancel this option Setting...

Страница 9: ...tivate the 46 F 8 C heating function heating set back The unit operates at a set temperature of 46 F 8 C The indoor unit display shows FP No icon will be displayed on the remote control NOTE This func...

Страница 10: ...until filter snaps in place 7 Close front panel on unit Fig 11 Filter Cleaning Indoor Unit Front Panel To clean the front panel on the indoor unit wipe the outside with a soft dry cloth Preparing for...

Страница 11: ...the display panel on the unit away from direct sunlight and heat as this may interfere with remote control transmissions Do not block air intakes and outlets on the indoor or outdoor units Energy Sav...

Страница 12: ...or units emit white mist When the unit restarts in HEAT mode after defrosting white mist may be emitted due to moisture generated from the defrosting process The indoor unit makes noises A rushing air...

Страница 13: ...structed Remove the obstruction The fan speed is too low Change the fan speed selection The operation mode is in Fan instead of Cool Change the operating mode to Cool or reset the unit Heating is Not...

Страница 14: ...Copyright 2018 CMNA 3300 Riverview Parkway Atlanta GA 30339 32802000102 Specifications subject to change without notice...

Отзывы: