7. Replacing the power cable
40
466790
V_02/06/2010
GB
6.8. Setting the pressure switch
The pressure switch is set at the factory.
Switch-on pressure 6 bar
Switch-off pressure 8 bar
6.9. Mounting the transport handle (Figures 10, 11)
Push the transport handle (9) into the brackets on the tank. Screw the transport handle tightly into
place using the fixing screws (K).
7. Replacing the power cable
If the power cable of this device is damaged, it may only be replaced by the manufacturer, their cus-
tomer service operation, or a similarly qualified person, in order to prevent risks.
8. Cleaning and maintenance
8.1. Cleaning
• Keep the safety devices free of dirt and dust as far as possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low pressure.
• We recommend that you clean the appliance immediately after you use it.
• Clean the appliance regularly with a damp cloth and some soft soap. Do not use cleaning
agents or solvents; these may be aggressive to the plastic parts in the appliance. Ensure that
no water can get into the interior of the appliance.
• You must disconnect the hose and any spraying tools from the compressor before cleaning. Do
not clean the compressor with water, solvents or the like.
8.2. Condensation water
Caution! In order to ensure the long life of the pressure tank (2), after each use, ensure that the con-
densation is drained by opening the drainage screw (11).
Check the pressure tank for rust and damages prior to each use. The compressor may not be oper-
ated if the pressure tank is damaged or rusty. If you locate any damage, please contact the cus-
tomer service workshop.
Attention!
Important!
Pull the power plug before doing any cleaning and maintenance work on the appliance
Attention!
Important!
Wait until the compressor has completely cooled down. Risk of burns!
Attention!
Important!
Always depressurize the tank before carrying out any cleaning and maintenance work.
Attention!
Important!
The condensation water from the pressure vessel will contain residual oil. Dispose of
the condensation water in an environmentally compatible manner at the appropriate
collection point.
466790.book Seite 40 Freitag, 25. Juni 2010 9:58 09