Operation
3.5. Trouble
Shooting
PROBLEM LIKELY
CAUSE
SOLUTION
Pre-wash/power wash
motor inoperative
Bad motor or capacitor
Faulty contactor
Replace defective motor
Replace contactor
Fuse is burned out
Replace fuse
Table limit switch
Remove dish rack at switch
Defective door reed switch
Replace reed switch
Defective start reed switch
Replace reed switch
Defective auto/manual switch
Replace switch
Machine inoperative
Defective 60 Sec. Timer
Replace timer
Defective 60 Sec. Timer or settings
Replace timer or change settings
Machine runs continuously
Contactor stuck
Replace contactor
Float switch
Check movement-replace it
Defective thermostat or setting
Replace thermostat or adjust
Defective heater contactor
Replace heater contactor
Defective heater
Replace heater
Defective heater switch
Replace switch
Heater (no heat)
Wire connections
Check and correct
Broken rack
Replace rack
Racks stuck
Tray track alignment
Adjust properly
Low incoming water supply
(150°F-low temp, 180 °F- high temp)
Check hot water supply
Thermostat setting
Adjust thermostat
Vent hoods
Close vents as much as possible
Low wash tank
temperature
Defective heater
Replace heater
Plugged rinse jets
Remove and clean
Pressure regulator out of adjustment Adjust
pressure
regulator
Water sol. valve coil or diaphragm
Replace or clean
Dirty rinse jets
Remove and clean jets
Low rinse water pressure
or no rinse
Defective rinse reed switch
Replace reed switch
Dispenser or settings
Check dispenser troubleshooting guide
Chemicals
Rinse pressure
Set 20 psi.
Quick drain on pre-wash end
Plumb quick drain back into pre-wash
tank above water line
Sheet pans
Use CMA sheet pan rack
Machine loosing water
Drain valves open
Close completely
Tank water level low
Check rinse pressure, drain valve open
Clogged jets
Clean jets
Low spray arm pressure
Motors connected wrong
Connect motors to reverse impeller
direction
MODEL CMA-44 Installation & Operation Manual Rev. 2 .15B
Page
21