MODEL CMA-181VL INSTALLATION & OPERATION MANUAL Rev. 1.00
Page
4
3.
The Cam Timer’s fourth cam powers ON the Drain Pump midway through the Rinse
Cycle and stays ON for 10 seconds, turning OFF 2 seconds after the Rinse Cycle has
completed. 3 seconds after the Wash Cycle has completed the Cam Timer’s second cam,
which controls the Rinse Cycle, turns ON—energizing the Water Solenoid—and stays ON
for 14 seconds. This 14-second period is the Rinse Cycle.
4.
After the Rinse Cycle is completed Cam Timer’s sixth cam turns Fan for 60 seconds steam
evacuation.
5.
The Cam Timer’s seventh cam controls the fill. The fill comes on 2 seconds after the fan
starts. Water fills into the booster until the fill pressure switch senses that the booster is
full and closes the water fill solenoid. The water fill solenoid will close before cam timer
times out.
6.
When the Cam Timer assembly approaches the final rinse portion of the cycle, the “Safe-
T-Temp” fifth micro switch will pause the cam timer assembly if the booster heater has
not reached 180 degrees. The Dishmachine will remain in wash cycle mode until a
minimum 180-degree rinse temperature is reached, at which time the Cam Timer will
advance automatically into the rinse cycle and dispense 180 degree rinse water over the
glasses.