MODEL CMA-181VL INSTALLATION & OPERATION MANUAL Rev. 1.00
Page
9
2.2.5. Booster Heater Setup
1. Turn the Power switch to the "ON" position.
The glass washer will be automatically filled with water to the correct level.
2. Turn the Power switch to the "OFF" position.
2.2.6. Installer Checklist
Glasswasher checked for concealed damage
Cold water supply is 41°F - 65°F
Incoming water supply line is ½” — minimum
Incoming water supply is 30 PSI minimum.
Supply circuit breaker for glass washer that is properly sized (50 amp)
Service voltage and phase type are correct to
unit’s data plate
Drain hose is installed with air gap (discharge 1” above drain)
Glasswasher is properly grounded
Glasswasher is properly leveled
C
ircuit breaker is labeled “GLASSWASHER”
Glass washer
has been “hard-wired” with correctly sized wire