12
1. The first setting will be
Total Vacuum Time
. Using the
Plus/Minus
keys set the
total time you want the vacuum cycle to last.
2. Press the
Right Arrow
key to move to the next setting. The VAC LED will
remain on. However you are now setting the
Vacuum On Time.
3. Using the
Plus/Minus
keys set the amount of time you want each vacuum pulse to
last.
4. Press the
Right Arrow
key to move to the next setting.
5. Using the
Plus/Minus
keys set the amount of time you want the vacuum to remain
off between each vacuum pulse.
6. You have now completed setting for a Pulsed Vacuum.
7. Press the
Right Arrow
key to move to your next setting.
E
. Multi Stage Vacuum / Gas:
This function allows your machine to perform multiple
vacuum and gas stages before moving onto the seal mode. Up to 10 vacuum / gas or gas /
vacuum stages may be set.
1. With the machine in the normal operation mode Press the Purge key indicated in
Figure 6. You will see a decimal point appear in the
Program Display.
The
machine can now be set for multi-stage operations that begin with a Vacuum
cycle. If you Press the Purge key once more the decimal point will begin to blink.
The machine will now perform multi-stage functions beginning with Gas.
Note:
The vacuum will engage for 2 seconds to hold the lid down before the first
gas stage begins.
2. Once you have engaged the Purge function then enter EDIT MODE (follow the
instructions indicated in point D on page 00).
3. The
VAC LED
will be lit and you will see a number appear in the
Time /
Percentage
display. This number indicates how many stages you wish to execute.
4. Press the
Plus / Minus
keys to set the number of stages you want.
5. Press the
Left Arrow
key. You will see that the LED above the word
VAC
stays
on.
6
.
Press the
Plus / Minus
Key to set the amount of Vacuum time for all of the
vacuum stages.
This second setting is ALWAYS the vacuum time.
7. Press the
Left arrow
key. You will see that the LED above the work
VAC
remains on.
8. Using the
Plus / Minus
keys set the amount of Gas time for all gas cycles. Note:
This third setting is always the Gas time
.
Note: If you Press the Purge key a third time the decimal point will disappear.
The Purge function is now OFF and your regular Vacuum & Gas settings will
resume.
Содержание Promax SC-800
Страница 18: ...16...
Страница 22: ...20 5 3 PNEUMATIC DIAGRAM...
Страница 23: ...21 5 4 ELECTRICAL DIAGRAM...
Страница 24: ...6 FABRICATION 22 6 2 WORKING BED BOTTOM 6 3 WORKING BED TOP 6 4 CHAMBER LID TOP 6 1 BODY 6 5 ELECTRICAL BOX...
Страница 25: ...6 1 BODY 23 SC80100000 Body Diagram...
Страница 27: ...6 2 1 WORKING BED LR 25 Cushion Bar Set Working Bed Diagram Top...
Страница 28: ...6 2 1 WORKING BED LR 26 Working Bed Diagram Bottom...
Страница 31: ...6 2 2 WORKING BED FB 29 Cushion Bar Set Working Bed Diagram Top...
Страница 32: ...6 2 2 WORKING BED FB 30 Working Bed Diagram Bottom...
Страница 35: ...6 3 1 LID DIAGRAM LR 33 SC80300A00 Lid Diagram...
Страница 37: ...6 3 2 LID DIAGRAM FB 35 SC80310000 Lid Diagram...
Страница 39: ...6 4 SEALING BAR STANDARD DIAGRAM 37 SC80320A00 Sealing Bar Standard Diagram...
Страница 41: ...6 4 SEALING BAR STANDARD DIAGRAM 39 SC80374A00 Sealing Bar Standard Diagram...
Страница 43: ...6 5 ELECTRICAL BOX 41...