TROUBLESHOOTING
Test Procedures
Page 11-20 2000 FE290 Gasoline Vehicle Maintenance and Service Supplement
11
Test Procedure 2, Continued:
7. Record the reading.
8. Return the electrolyte to the cell from which it was taken. Replace vent cap.
9. Repeat steps 2-8 on all cells.
Hydrometer Calibration
Most hydrometers are calibrated to read correctly at 80 °F (27 °C). The readings obtained as described
above must be corrected for temperature. For each 10 °F (5.6 °C) above 80 °F (27 °C), add 0.004 to the
reading. For each 10 °F (5.6 °C) below 80°F (27 °C), subtract 0.004 from the reading.
Interpreting the Results of the Hydrometer Test
The approximate state of charge can be determined from the following table:
If the difference between the cells is 0.020 or more, the low cell should be suspected. It may require a catch-
up charge or it may be a weak cell. When the variations between cells reach 0.050 or more, the battery
should be replaced.
Figure 11-23 Battery Electrolyte Level
Figure 11-24 Reading Hydrometer
SPECIFIC GRAVITY AT 80 °F (27 °C)
STATE OF CHARGE
1.250 - 1.280
100%
1.220 - 1.240
75%
1.190 - 1.210
50%
1.160 - 1.180
25%
ELECTROLYTE
LEVEL AT LEAST
1/2 INCH (13 MM)
ABOVE PLATES
OR TO LEVEL
INDICATOR
PLATES
BATTERY
CAP
HYDROMETER
TEST
Hold the hydrometer
at eye level. Read the
scale at the level of
the electrolyte.
Содержание FE290
Страница 2: ......
Страница 18: ...10...
Страница 56: ...11...
Страница 88: ...12...
Страница 166: ...14...
Страница 170: ...15...
Страница 212: ...16...
Страница 228: ...17...
Страница 234: ......
Страница 235: ......
Страница 236: ...Golf Cars and Utility Vehicles Club Car Inc P O Box 204658 Augusta GA 30917 4658...