POWERDRIVE 2 CHARGER (EXTERNAL)
Charger Installation and Operation
Page 5-4
2008-2011 Domestic Battery Charger Maintenance and Service Manual
5
CHARGER INSTALLATION AND OPERATION
See General Warning, Section 1, Page 1-1. See additional WARNING on page 5-1.
ý
DANGER
• The charging area must be ventilated. Hydrogen level in the air must never exceed 2%. The
total volume of air in the charging area must be changed five times per hour. Exhaust fans
should be located at the highest point of the roof. Contact a local HVAC engineer.
• Do not charge the vehicle batteries with the vehicle covered or enclosed. Any enclosure or
cover should be removed or unzipped and pulled back when batteries are being charged. An
accumulation of hydrogen gas could result in an explosion.
Figure 5-3 Charge Circuit and Battery Configuration – Precedent Vehicles
S1
S2
B+
M–
B–
1
2
3
4
#10 BLA
CK
#6 RED
#6 BLA
CK
#6 BLA
CK
#6 BLA
CK
BATTERY
BANK
#10 BLA
CK
#10 RED
#18 GRA
Y
ONBOARD
COMPUTER
FRONT
OF VEHICLE
SINGLE
POSITION
CONNECTOR
CHARGER
RECEPTACLE
SOLID STATE
SPEED CONTROLLER
TO SOLENOID
Содержание 2008-2011
Страница 2: ......
Страница 12: ...Page x 2008 2011 Domestic Battery Charger Maintenance and Service Manual ...
Страница 18: ...1 ...
Страница 28: ...2 ...
Страница 64: ...3 ...
Страница 100: ...4 ...
Страница 132: ...5 ...
Страница 168: ...6 ...
Страница 204: ...7 ...
Страница 296: ...Club Car R NOTES ...
Страница 298: ......
Страница 299: ......