Cloudray Laser System
Cloudray (Jiangsu) Co., Ltd.
8
Electrical Safety Instructions
•
ONLY use this device with a compatible and stable power supply with less than 5%
fluctuation in its voltage.
•
ONLY turn on the power to this device when it is well grounded, either via a firm
connection to a 3-prong outlet or via a dedicated grounding cable firmly connected to the
proper slot on the back of the main tower. Do not use with an ungrounded 3 to 2 prong
adapter. The device's grounding should be checked regularly for any damage to the line or
loose connections.
•
Turn the device on and off using its key and power buttons in the correct order. The
mainboard, galvo, and laser have separate power supplies that are grounded in order.
Activating everything at once, too quickly, or in the wrong order may send electrical current to
an ungrounded component, causing short circuits and other electrical hazards.
•
ONLY use this device with one hand at a time. The laser is powered by an extremely
high voltage connection and placing two hands on the machine at one time during operation
has the potential to create a closed circuit with the human body, resulting in electrical shock.
•
The area around this laser marking device should be kept dry, well ventilated, and
environmentally controlled to keep the ambient temperature between 40
–95°F (5–35°C). The
ambient humidity should not exceed 70%.
•
Adjustment, maintenance, and repair of the electrical components of this device must be
done ONLY by trained and skilled professionals to avoid fires and other malfunctions,
including potential radiation exposure from damage to the laser components. Because
specialized techniques are required for testing the electrical components of this marking
system, it is recommended such testing only be done by the manufacturer, seller, or repair
service.
•
Unless otherwise specified, ONLY undertake adjustment, maintenance, and repair of the
device when it is turned off and disconnected from its power supply.
Material Safety Instructions
•
Users of this fiber marking machine are responsible for confirming that materials to be
processed can withstand the heat of a class 4 laser and will not produce any emissions or
DO NOT connect other devices to the same fuse, as the laser system will
require its full amperage. Do not use with standard extension cords or
power strips. Use only surge protectors rated over 2000J.
Содержание LiteMarker
Страница 1: ...Cloudray Laser System Cloudray Jiangsu Co Ltd I LiteMarker Laser System User Guide Version 2 1 2022 04...
Страница 9: ...Cloudray Laser System Cloudray Jiangsu Co Ltd 4 EC Declaration of Conformity...
Страница 36: ...Cloudray Laser System Cloudray Jiangsu Co Ltd 31 2 Menu bar Laser Split Mark2 Set Parameters...
Страница 38: ...Cloudray Laser System Cloudray Jiangsu Co Ltd 33 4 Press Mark F2 the fiber laser will mark your image...