be read as a ‘1’ when the level is higher than 4.1V.
Levels in between are undefined/unpredictable.
The explanation about the ignition sense feature and how to use it can be found in the
Software Developer Kit, under the title "How to use the ignition sense".
Power Consumption
You can find here a document describing all the different power consumption numbers
Preventing Fuse Overload
SAFETY WARNING
On old CloudGate models, a huge inrush current caused by capacitors inside the
CloudGate may cause an internal fuse to break. When using an external power supply
with an output voltage higher than 15V, Option recommends using a special cable
which will reduce the amplitude of these charge currents. This cable can be obtained
at your CloudGate distributor.
If the fifth digit of the serial number of the CloudGate is a "C", the CloudGate is an older
model and susceptible to this remark. If the fifth digit is not a "C", the fuse of your
CloudGate will not get broken due to these charge currents.