1.2.5. Power Requirements
Base Unit Power Supply
The symbol on the label at the bottom side of the CloudGate shows the power
requirements:
Input voltage must be between 9V - 33V DC
Internal electronic fuse limits the input current to 1.2A
For the power cable between the external power supply unit and the CloudGate
Option recommends to use a power cable that has a wire thickness of
22 AWG!
SAFETY WARNING
This CloudGate operates on DC power provided by a DC power supply or by an AC
power adapter. Only use power supplies in the range 9-33V DC and make sure the
product is installed near a power outlet that is easily accessible.
When using the KNX card, only use a 24Vdc power supply.
SAFETY WARNING
When using an AC adapter make sure that the ambient temperature doesn’t exceed
the specified temperature limits of the AC adapter.
SAFETY WARNING
The CloudGate is regarded a Class III equipment: this means that the protection against
electrical shock is provided by means of power supplied by an SELV (Safety Extra Low
Voltage) circuit and that the CloudGate does not generate hazardous voltages within
itself.
When using an AC power adapter make sure it provides protection against electrical
shock, class II, and that it is certified for the country where it will be used.
As a reference, the power supply available from Option has the following parameters:
Output voltage 12V DC
Max output current 1A
In case you would like to use an industrial power supply Option recommends the next:
http://www.us.tdk-lambda.com/ftp/Specs/dspa.pdf
It can be sourced through Farnel, Mouser, Digikey, ...
12