background image

Z4-8

MK3

 Installation and User Guide v1.2

14

Connecting an RL-1 Series remote control plate

Wire the remote control plate as shown below. Either single-
core screened or twin-and-screen cable may be used; in the 
case of the latter, ignore one of the cores. Maximum reliable 
cable run is 100 m.

1

2 3

REMOTE

LEVEL

1 2 3

REMOTE LEVEL CONTROL WIRING

RL-1

SINGLE-CORE SCREENED CABLE MAY BE USED

Before the RL-1 will operate, the zone’s Music Control Port 
must be enabled by setting the adjacent push-button switch 
([14] on page 9

)  to  REMOTE  (i.e.,  pressing  it  in).  In  this 

setting, the zone’s front panel Music Level and Source Select 
controls become inoperative. As music source selection will 
still be required from the mixer’s front panel when an RL-1 
is in use, the REMOTE setting may be overridden 

for the 

source selection control only

 by moving internal jumper J1 

on the sub-board for the zone in question. See page 22 for 
location of internal jumpers.

Connecting an RSL-6 Series remote control plate

Wire the remote control plate as shown below. Twin-and-
screen cable should be used. Maximum reliable cable run is 
100 m.

1 2 3

REMOTE SOURCE & LEVEL CONTROL WIRING

RSL-6

USE TWO-CORE SCREENED CABLE

1 2 3

REMOTE

LEVEL

Before the RSL-6 will operate, the zone’s Music Control Port 
must be enabled by setting the adjacent push-button switch 
([14] on page 9

)  to  REMOTE  (i.e.,  pressing  it  in).  In  this 

setting, the zone’s front panel Music Level and Source Select 
controls become inoperative.

Music Mute

External muting of music is available at the MUSIC MUTE 
connector. National or Local Authority regulations governing 
such systems may require that normal programme material 

(i.e., music) should be muted in an emergency, to ensure that 

any emergency messages are clearly audible.
The Music Mute input is on a 2-pin 5 mm-pitch screw-terminal 
connector. It should be connected to the appropriate alarm 
output on whichever building management system registers 

the alarm (typically the Fire System). The alarm output must 

be volt-free; if no such output is available, an intermediate 
relay or other isolation device must be installed between the 
alarm output and the Music Mute input.
The Mute input can be set to operate on either normally 

open (N/O) or normally closed (N/C) contacts via an internal 

jumper (see page 22

). The  factory  default  setting  is  N/O, 

thus requiring a short-circuit to be applied across the two 
pins of the connector for muting to occur.
Visual indication of muting being activated is given by the 
Music Mute LED on the front panel.

1

2

MUSIC MUTE 

INPUT

RELAY

NORMALLY OPEN (N/O) 

CONNECTION

1

2

MUSIC MUTE 

INPUT

RELAY

NORMALLY CLOSED (N/C) 

CONNECTION

Содержание Z4MK3

Страница 1: ...10 0 Zone 2 10 0 10 0 10 0 10 0 Zone 3 10 0 10 0 10 0 10 0 Zone 4 10 0 10 0 10 0 10 0 MK3 1 2 3 4 5 6 Eight Zone Venue Mixer 8 Power Mute Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Music...

Страница 2: ...eatures 5 Optional System Components 6 LM 2 Mic line input module with remote music control 6 RSL 6 Series Remote Music Level source Control 6 PM Series paging microphones 7 PM1 paging microphone 7 Bl...

Страница 3: ...17 Microphone priority over input at Facility Port 17 OPTIONS AND ADDITIONAL INFORMATION 18 LM 2 active input modules general considerations 18 Connecting multiple LM 2s 18 Using the Facility Ports as...

Страница 4: ...t magnitude to constitute a risk of electric shock The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing i...

Страница 5: ...technical specifications The Z8MK3 Z4MK3 manual includes full details of the optional LM 2 remote input module Basic information on interfacing Cloud PM Series paging microphones and connecting the RL...

Страница 6: ...Control Plate permitting control of zone music level and source The LM 2 connects to one of the unit s Facility Ports via screened Cat 5 cable and the remote inputs are fed to that zone only The mixer...

Страница 7: ...12 16 paging mic on page 12 for more information PM1 paging microphone The Cloud PM1 paging microphone is also compatible with the Z8MK3 and Z4MK3 It is a much simpler unit which addresses only one zo...

Страница 8: ...HONE 1 adjusts the level of the microphone connected at Mic 1 input in each zone See page 15 4 MICROPHONE 2 adjusts the level of the microphone connected at Mic 2 input in each zone See page 15 5 PAGI...

Страница 9: ...7 PAGING MIC GAIN as 4 See page 16 8 PAGING MIC EQ as 5 See page 16 9 PAGING MIC ACCESS PORT 6 pin Z4MK3 or 10 pin Z8MK3 5 mm pitch screw terminal connector for per zone contact closure paging access...

Страница 10: ...r has an extra cavity for storing a spare fuse note that the active fuse is that in the inner cavity System Connections Music Sources Connect the system s various music sources to LINE 1 to LINE 6 All...

Страница 11: ...pin 2 cold pin 3 hot When using single core cable don t connect cold at the Z8II Z4II Unbalanced input e g phono 1 3 2 SC SCN Z8II Z4II Balanced output pin 1 ground pin 2 cold pin 3 hot Unbalanced in...

Страница 12: ...Zone s Music Control Port The LM 2 s upper PCB is fitted with an RJ45 connector labelled OUTPUT Connect this to the Facility Port of the relevant Zone using screened Cat 5 cable with screened RJ45s a...

Страница 13: ...responding to the zone s in which announcements are required Any or all of the zones may be paralleled if multiple zones need to operate from the PM1 An alternative method for achieving paging to all...

Страница 14: ...fore the RSL 6 will operate the zone s Music Control Port must be enabled by setting the adjacent push button switch 14 on page 9 to REMOTE i e pressing it in In this setting the zone s front panel Mu...

Страница 15: ...e rear panel switch setting the front panel control in LOCAL and via a remote plate or other external control in REMOTE If the jumper is set to FR the source selection will always be made with the fro...

Страница 16: ...via internal jumpers and should be set to suit the requirements of the installation when the system is installed See page 22 for location of the internal jumpers Mic 1 Mic 2 priority By default fully...

Страница 17: ...the priority is selected a signal present at Line 6 will force the zone s source selection to that input when the signal disappears the previously selected source will be restored over the time const...

Страница 18: ...acility Port the chain is connected Remember to consider the current drawn by any additional input modules see page 24 for details of current consumption and PSU capability See also the section below...

Страница 19: ...hey may be used to receive DC voltages from the external system to effect these adjustments Both music source selection and level can be controlled over their full ranges with a DC voltage of 0 to 10V...

Страница 20: ...to be selected The output impedance of the control voltage source should be low enough to overcome the effect of this resistor Fitting loudspeaker EQ cards The Z4MK3 and Z8MK3 are compatible with vari...

Страница 21: ...system where four possible music or other audio sources are made available to three or more zones areas Only three are shown for clarity Points to note Area 1 and Area 3 have remote control plates in...

Страница 22: ...ase time ABSENT 12 seconds release time 3S J4 Mic priority over facility input OFF No priority ON MIC 1 2 paging mic haveVOX triggered priority over signals at facility port OFF J5 Paging mic priority...

Страница 23: ...E 7 Z8MK3 ONLY KEY Jumper with two possible positions black square indicates factory default setting J1 J2 J3 J4 Motherboard jumper locations SOCKET FOR OPTIONAL EQ CARD J8 J1 J4 J5 J2 J6 COMPONENT SI...

Страница 24: ...fending signal source can often be identified by setting the volume control to minimum then disconnecting the input leads both left right channels on each line input until the hum disappears This prob...

Страница 25: ...Impedance 2 kohms balanced Phantom power 15V PCB jumper for on off Headroom 20 dB Noise 120 dB EIN 22 Hz 22 kHz 150 ohms Equalisation HF 10 dB 5 kHz LF 10 dB 100 Hz Facility Input Input Impedance 10...

Страница 26: ...Z4 8MK3 Installation and User Guide v1 2 26...

Страница 27: ...Z4 8MK3 Installation and User Guide v1 2 27...

Страница 28: ...Z4 8MK3 Installation and User Guide v1 2 28...

Страница 29: ...Z4 8MK3 Installation and User Guide v1 2 29...

Страница 30: ...Z4 8MK3 Installation and User Guide v1 2 30...

Страница 31: ...Z4 8MK3 Installation and User Guide v1 2 31...

Страница 32: ...ngland Tel 44 0 114 244 7051 Fax 44 0 114 242 5462 email info cloud co uk web www cloud co uk Cloud Electronics USA 2065 Sidewinder Drive Suite 200 Park City Utah 84060 United States of America Toll F...

Отзывы: