(1(5*<5(&29(5<
3DUWLDOKHDWUHFRYHU\'
Desuperheaters, shell and tube type are used to reclaim a
small portion (around 20%) of the total condenser heat.
7RWDOKHDWUHFRYHUH\5
Heat recovery water cooled condenser, shell and tube
type, are used to remove 100% of the condenser heat to
produce hot water.
/2:7(03(5$785(
:DWHUORZWHPSHUDWXUH%
Range of application of this version is between +5°C
down
to
–8°C,
using
glycol
solution.
Available versions:
•
Brine chiller
•
Double set-point function
The availability of reduction capacity steps by means of
solenoid valve for the compressor depends on the
application temperature range. Please call our commercial
dept. for details.
* ( Compatible with versions: D - R - FCD )
(1(5*<6$9,1*6
'LUHFW)UHH&RROLQJ)&'
Version that allows to recovery free-cooling from ambient
when tha ambient air temperature is lower than the system
outlet water temperature.
$&2867,&&21),*85$7,21
6WDQGDUG67
6RXQGSURRIHGFRPSUHVVRUV6&
this configuration is provided with compressor acoustical
enclosure.
ORZQRLVH/1
this configuration is obtained by inserting the compressors
in a soundproofed chamber and reducing the speed of the
fans, with a larger condensing section.
([WUHPHO\ORZQRLVH(1
with reference to configuration LN, flexible connection
joints are also used, together with vibration-damping
springs/rubber on the compressors.
(1(5*<()),&,(1&<
7HPSHUDWHFOLPDWLFFRQGLWLRQ7
standard
+($7(;&+$1*(56$33529$/6
&( 3('(XURSHDQWHVWLQJ
& &/,9(7,QWHUQDOWHVWLQJ
64/
$&&(6625,(6
Units can be supplied with the following optional
accessories:
- condenser coil in copper/acrylic protection on
aluminium
- condenser coil in copper/copper
- condenser coil in copper/copper electrotinned
- ECOBreeze
- capacitors to increase power factor (cosfi > 0.9)
- electronic expansion valves
- set point compensation with 4-20 mA signal
- set point compensation with outside temperature probe
- set point compensation according to outdoor Enthalpy
- double operation set point with unit in version “B”
- data logger
- remote microprocessor module
- spring antivibration mounts
- rubber antivibration mounts
(;&+$1*(586(/,0,76
,QWHUQDOH[FKDQJHU
Maximum operating pressure at refrigerant side
Maximum operating pressure at
water side
Standard
(kPa)
Low temperature (kPa)
kPa
&/,9(7
(C)
2500
2100
1000
3('
(CE)
2900
2100
1600
64/
2450
2100
1000