Dimensional drawings

SIZE 1

DAA5Gsize1_0
Date: 21/09/2012

(1)   Capacity modulating compressor

(2)  Electrical panel

(3)   Power input

(4)   Condensation drain pipe Ø 20 mm

(5)   Standard outdoor air exchanger (below)

(6)   Exhaust air standard exchanger (above)

(7)   Capacity modulating post-heating with hot gas recovery

(8)   Hydronic recovery device for extended operating range (Optional)

(9)   Electrical heaters

(10)   Electronic filters

(11)   Class G4 air filters on outdoor and exhaust air

(12)   Supply fan (below)

(13)   Exhaust fan (above)

(14)   Air filters access

(15)   Grid for indoor installation (Optional)

(16)   Lifting holes

(17)  Functional spaces

(18)   If the unit is placed against the wall provide the space for the replacement of the roof electric fan

(R)   Return Air

(M)   Supply Air

(AE)  Outdoor air intake

(ES)   Exhaust air

WEIGHT DISTRIBUTION

Size

Size 1

W1 Supporting Point

kg

78

W2 Supporting Point

kg

82

W3 Supporting Point

kg

82

W4 Supporting Point

kg

78

Shipping weight

kg

320

54

Содержание CPAN-XHE3

Страница 1: ...Installation use and maintenance manual Make up unit full fresh air With return exhaust and thermodynamic heat recovery Reversible heat pump technology CPAN XHE3 size1 size6 M05G40L12 04 17 11 16...

Страница 2: ...im is that to offer its customers developed systems that assure the best comfort reduce energy consumptions and installation and maintenance costs for the entire life span of the system With this manu...

Страница 3: ...ections 9 5 Aeraulic connections 11 6 Electric connections 13 7 Start up 19 8 Control 28 9 Maintenance 39 10 Residue risks 45 11 Disposal 46 12 Technical information 47 The data contained in this manu...

Страница 4: ...perations must be carried out in accordance with the local safety standards Periodical checks Carry out periodical checks to identify any loose damaged or broken parts The lack in repair entails the r...

Страница 5: ...Range Size Serial number Year of manufacture Wiring diagram 1 2 Machine identification 1 GENERALITY VERSIONS RTA Active thermodynamic recovery standard std REFRIGERANT CIRCUIT CCSTD Standard exchanger...

Страница 6: ...ith reserve for evident shortages damages due to transport notices via fax and with registered letter with acknowledgement receipt to carrier and supplier The notifications must be made within 8 days...

Страница 7: ...following criteria level of sound emissions admitted by the local standards Customer approval safely accessible position technical spaces requested by the unit maximum distance admitted from the elec...

Страница 8: ...eam line in a position higher to the unit If the available steam supply exceeds the pressure operating range indicated the required de pressurization must take place outside the unit responsibility of...

Страница 9: ...ee a siphon that by eliminating the depression caused by the fan prevents suction of air from the drain piping The piping must have adequate slope to allow out flow Anchor the piping with an adequate...

Страница 10: ...ium high conductivity in an immersed electrode humidifier min max Hydrogen ions pH 7 8 5 Specific conductivity at 20 C S cm 300 1250 Total dissolved solids TDS mg l 1 1 Dry residue at 180 C R 180 mg l...

Страница 11: ...in particular with high air speed or bends with reduced radius 5 1 Generality The internal surface of the channel must be smooth enable its washing and must not contaminate the air Thermally isolate t...

Страница 12: ...12 5 AERAULIC CONNECTIONS 1 2 3 Remote supply air sensor standard size 3 4 5 6 1 Probe kit position 2 Probe cable outlet...

Страница 13: ...ower supply cables and of the protective cable must be determined in accordance with the features of the used protections All electrical operations must be carried out by personnel having the legal re...

Страница 14: ...emote ON OFF selector SA5 remote SUMMER WINTER selector HLC1 compressor status signal lamp HLM supply fan status HLE indicating light of the return and or supply fan status ALM remote alarm signal 6 7...

Страница 15: ...15 6 9 SERVICE KEYPAD OPTION 6 8 P C not supplied Shift RJ45 from T IP to T HI RJ45 standard connection 6 ELECTRIC CONNECTIONS...

Страница 16: ...eypad Distance up to 350 mt Connections Distance up to 700 mt A user interface B B1 KNX bus max 350 mt twisted pair with shield 0 8 mm EIB KNX cable marking recommended C power supply unit N125 11 5WG...

Страница 17: ...ble arresters must be set up to protect the serial lines from the effects of the atmospheric discharges A 120 ohm resistance must be located on the end of the serial line Alternatively when the last s...

Страница 18: ...ED BUS communication with BACNET green ready for communication yellow startup red BACnet server down restart after 3 sec LED BSP communication with AP1 module green communication ok yellow software ok...

Страница 19: ...it visual control earth connection unit powered by fixed network or by electrogen group electric connections by customer unit ON power supply Powered unit compressor carter heaters ON from at least 8...

Страница 20: ...humidifier options 1 Find out if before connecting the unit the hydraulic system has been washed and the washing water drained 2 Check the hydraulic circuit has been loaded and pressurised 3 Check th...

Страница 21: ...of start up for all units Periodical checks to be carried out as frequently as defined by the Manufacturer see MAINTENANCE section 7 15 EC Directive 97 23 PED Check the air and water temperatures are...

Страница 22: ...002 SetQAirPlant Main index Parameter machine Plant config Variable air flow rate CO2 probe connected to the X2 input set P0032 X2Config CO2 Main index Parameter machine configure machine set air flow...

Страница 23: ...Parameter machine Thermoregulator P0070 LimMinSupplyT P0071 LimMaxSupplyT P0072 MC_BandPr P0073 MC_DeadBand Humidity setpoint Main index Parameter machine Plant config set the specific supply humidit...

Страница 24: ...e The air flow rate control depends on the device connected to the X2 input Constant air flow rate X2 input not used set P0032 X2Config None Main index Parameter machine configure machine set rated ai...

Страница 25: ...SetHeat P0010 CS_TExtCool P0011 CS_TExtHeat P0012 CS_GainCool Ycool Xcool P0013 CS_GainHeat Yheat Xheat Humidity setpoint Main index Parameter machine Plant config set the specific supply humidity se...

Страница 26: ...ex Parameter machine Plant config set air flow rate with quality met P0004SetQAirCO2Ok P0004 P0002 Main index Parameter machine Plant config Constant supply pressure pressure detector connected to the...

Страница 27: ...idity setpoint Main index Parameter machine Plant config set the specific return humidity setpoint in heating mode P0018 SetXSR Confirm configuration Main index Parameter machine Plant config set P002...

Страница 28: ...OOL mode change CLEAN function prolonged pressure Symbols ON OFF OFF status On the top field of the thermostat the temperature and OFF indication are alternated every 2 seconds When the status is OFF...

Страница 29: ...7 confirm scroll the parameters enable the parameter change P1 starts flashing change the value of the parameter confirm the new value select to enable the new value and exit when the time is displaye...

Страница 30: ...y temperature 3 Return specific humidity 4 Outdoor specific humidity 5 Supply specific humidity 6 Air quality option 7 Active compressors number 8 Compressors fuctioning mode 0 off 1 cool 2 heat 9 Act...

Страница 31: ...ll keys disabled select to confirm exit 16 3 C 17 00 COD _ _ _ _ T0 ON Key code table n key key n key key T0 T5 T1 T6 T2 T7 T3 ALL All keys T4 T1 OFF ALL OFF ESC 16 3 C 17 00 8 3 DATE AND HOUR Press H...

Страница 32: ...ress 7 days since the alarm was triggered 17 00 alarm time previous menu scroll the alarms exit without alarms RESET exit with alarms RESET scroll and select RES 8 5 TO VISUALIZE ALARM IN PROGRESS Bef...

Страница 33: ...t scheduled the unit remains in ECO mode Scheduling example 7 starts flashing to confirm selected days press 1 3 4 starts flashing press press ref A starts flashing set time of the event press Enable...

Страница 34: ...P 16 3 C 17 00 4 P flashing active scheduling Press 2 sec press to schedule day 3 press Wednesday press 3 stays steady press 7 starts flashing press to confirm selected days press select the event 3...

Страница 35: ...reases value Confirm Password 1 7 27 03 2013 10 15 30 Supply T Setpoint 22 0 C Supply X Setpoint 10 0 g kg StatoAttuale ON Cmp 23 Res Off Battery Off 8 8 COMMON OPERATIONS ON OFF ECO main menu cmd loc...

Страница 36: ...lay actual value On pag xy unit parameters service maintenance P0500 1 Setting Exit Select Confirm d01 Monday Scheduled day Active Time 1 xx yy Value 1 Eco Time 2 Value 2 Time 3 Value 3 Setting Exit d...

Страница 37: ...e 3 eE001 Monitore fase Fault EE003 Guasto P1 Util Ok EE003 Guasto P1 Util Fault Press alarm log reset alarms access Before resetting an alarm identify and remove its cause Repeated resets can cause i...

Страница 38: ...haustPDiff Differential pressure trasducer exaust fan fault ee039 PSupply Pressure trasducer suply fan fault ee044 Humidifier alarm Humidifier board disconnected ee050 H2O plant temp Plant water tempe...

Страница 39: ...28 Discharge pressure High pressure probe fault ee229 Suction pressure Low pressure probe fault ff055 Room condition Heat mode Heat mode room temperature too low outside operating limits ff056 Outdoor...

Страница 40: ...munication inv1 C2 Missing comunication compressor 1 inverter circuit 2 FF239 Timeout comunication inv1 C2 Missing comunication compressor 1 inverter circuit 2 FF240 Alarm Inverter 2 on Circuit 2 comp...

Страница 41: ...ea connection LAN 6 Select Internet protocol version 4 TPC IPV4 and enter Property 7 Set the IP address 192 168 1 100 8 Set Subnet mask as 255 255 255 0 9 confirm OK 10 Enter Start Windows button 11 W...

Страница 42: ...asurement channelling anti vibration devices and fastenings check power supply cable isolation and fastening check earth cable check electric control board cleaning power remote controls state clamps...

Страница 43: ...he START UP section Plan in advance the technician intervention to prevent misunderstandings and be able to use the system when required 9 5 Stand by i i 9 6 Structure Check the state of the parts con...

Страница 44: ...elimination of residues 6 Rinse the filter with a jet of water or using a low pressure water jet machine 7 Leave the electrostatic cells to dry in a hot room or directly in the sun for a few hours Kee...

Страница 45: ...wl to check the regular outflow 9 9 Condensate collection bowl 9 MAINTENANCE 9 10 Indoor air coil Accidental contact with the exchanger flaps can cause injuries from cut use protective gloves The finn...

Страница 46: ...emptying of the cylinder to avoid ice forming replacement of the cylinder The manual drainage is carried out by means of selector SA7 see ELECTRIC CONNECTIONS chapter REPLACEMENT OF THE CYLINDER To re...

Страница 47: ...g the correct fastening of all fastening screws of the panelling can cause damages to things persons or the unit itself Periodically check closing of all panels and their correct fastening In the even...

Страница 48: ...bol at the side With a view of respecting the environment our units are manufactured in accordance with EC Directive on waste electric and electronic equipment WEEE The potential effects on the enviro...

Страница 49: ...96 9 Compressor power input 4 kW 2 28 3 77 7 13 11 2 14 4 18 3 COP_C 4 4 61 4 72 5 21 5 20 5 33 5 29 Operation with high airflow Maximum air flow Nominal air flow l s 528 972 1944 2556 3194 3889 Nomin...

Страница 50: ...ower kW 0 80 0 90 2 70 2 80 2 80 2 70 Max static pressure supply fan Pa 630 630 630 600 420 630 Fans Exhaust Type of exhaust fan RAD RAD RAD RAD RAD RAD Number of exhaust fans No 1 1 1 1 1 2 Fan diame...

Страница 51: ...d power level dB Sound pressure level Sound power level Octave band Hz 63 125 250 500 1000 2000 4000 8000 dB A dB A Size 1 59 60 65 69 72 72 63 69 60 77 Size 2 60 61 66 70 73 73 65 70 61 78 SIZE 3 66...

Страница 52: ...overy device withT_RA 26 D B 4 With option RECH Hydronic recovery device withT_RA 24 D B 5 With option RECH Hydronic recovery device withT_RA 22 D B T_OA outdoor air temperature T_RA extracted air tem...

Страница 53: ...H Hydronic recovery device T_OA outdoor air temperature DB dry bulb WB wet bulb Extracted air 1 Normal operating range 2 Operation in which they could be defrost cycles T_RA extracted air temperature...

Страница 54: ...ctrical heaters 10 Electronic filters 11 Class G4 air filters on outdoor and exhaust air 12 Supply fan below 13 Exhaust fan above 14 Air filters access 15 Grid for indoor installation Optional 16 Lift...

Страница 55: ...rs 10 Electronic filters 11 Class G4 air filters on outdoor and exhaust air 12 Supply fan below 13 Exhaust fan above 14 Air filters access 15 Grid for indoor installation Optional 16 Lifting holes 17...

Страница 56: ...11 Class G4 air filters on outdoor and exhaust air 12 Supply fan below 13 Exhaust fan above 14 Air filters access 15 Grid for indoor installation Optional 16 Support brackets can be removed after the...

Страница 57: ...11 Class G4 air filters on outdoor and exhaust air 12 Supply fan below 13 Exhaust fan above 14 Air filters access 15 Grid for indoor installation Optional 16 Support brackets can be removed after the...

Страница 58: ...11 Class G4 air filters on outdoor and exhaust air 12 Supply fan below 13 Exhaust fan above 14 Air filters access 15 Grid for indoor installation Optional 16 Support brackets can be removed after the...

Страница 59: ...11 Class G4 air filters on outdoor and exhaust air 12 Supply fan below 13 Exhaust fan above 14 Air filters access 15 Grid for indoor installation Optional 16 Support brackets can be removed after the...

Страница 60: ...nfo clivetcomercial com CLIVET ESPA A S A U Service and Maintenance Division Calle Real de Burgos N 12 28860 Paracuellos del Jarama Madrid Espa a Tel 34 91 6658280 Fax 34 91 6657806 info clivet es CLI...

Отзывы: