16
③
Set the connection parameters of the console emulation program by the following steps
below:
(For more details on the connection parameters, refer to the user guide of the console
emulation program.)
Port: COM port number of the computer where the serial cable is connected.
Baud rate: 115200 bps
Data Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
The example below displays the console through the serial interface after booting the CG-410 is
completed successfully.
System Ready...
④
Enter “ipcfg <enter>”, then the message below will appear. You can select one of the IP
address configuration methods among; 0 (Static IP) / 1(DHCP) / 2(ADSL) that matches your
network environment.
[email protected]> ipcfg <enter>
IP Configuration Help
Help display this message
Exit exit from this menu
Select IP configuration method
0) Static IP
1) DHCP
2) ADSL
ipcfg >
⑤
When you complete the network settings, a message asking if all of the parameters have
been set correctly will appear. Type “Y <enter>” to save the parameters.
The example below shows the confirmation message when the IP setting mode is set as “Static
Содержание CG-410