Clint TCW 104 Скачать руководство пользователя страница 6

2.8 Jednostka dla systemu 2 i 4 rurowego: modele 84÷104

Schemat elektryczny: warianty konstrukcyjne mogą wymagać modyfi-

kacji, zawsze korzystaj ze schematu dołączonego do urządzenia.

2.8 Unit for 2 and 4 pipes system: models

 84 - 104

Main layout: the variants made in the constructions can involve modi

-

cations. Always refer to the layout supplied with the product.  

Jednostka dla systemu 2-rurowe-

go, z zaworem lub bez, z panelem 

sterowania DRM.

Unit for system with 2 pipes, with 

or without valve, with DRM control 

panel.

PE L

N

N L

230 V

ac

~

230 V

 

- 50 

Hz

M

in

M

e

d

M

ax

1

3

2

4

Q1

230V-50H

z

3

L

PE

2

1

1

N

QG

4

3

53

YF

2

KRX

BU

BN

4

14

11

15

54

3

56

5

4

55

55

56

56

55

54

54

MED

56

MAX

CV2

54

MV2

55

MIN

53

WH

55

56

56

MV

1

55

54

54

53

53

3

12

KRX

22

KRX

7

15

9

8

8

32

9

24

16

10

31

10

34

X

15

KRX

FV

U

A1

BU

A2

OG

16

20

2

20

21

53

53

CV

1

14

1

14

16

MP

17

19

SB

BK

BK

19

MAX

MED

MIN

WH

6

GN/YE

PE L

N

N L

230 V

ac

~

230 V

 

- 50 

Hz

M

in

M

e

d

M

ax

1

3

2

4

Q1

SM

Jednostka dla systemu 2-rurowe-

go, z zaworem lub bez, z panelem 

sterowania DRA.

Unit for system with 2 pipes, with 

or without valve, with DRA control 

panel.

PE L

N

3

4 5

1

7

6

2

16 17 18

19

14

N L

230 V

ac

~

230 V -

 

50

 Hz

M

in

M

e

d

M

ax

20

15

1

3

2

4

Q1

SM

6

7

Jednostka dla systemu 4-rurowego

z dwoma zaworami lub dla systemu

2-rurowego, z zaworem lub bez, 

grzałką elektryczną i panelem ste-

rowania DRA.

Unit for system with 4 pipes, with 

two valves, or with 2 pipes, with or 

without valve and  electric heater, 

with DRA control panel.

CV2

53

KRX

230V-50H

z

L

PE

2

1

1

N

QG

4

3

3

53

BU

YF

55

56

GY

BU

54

MV2

OG

WH

12

BU

13

MAX

2 3

BN

14

4

15

11

56

4 5

MIN

54

55

BU

MED

YC

3

54

54

56

56

56

56

GY

55

55

54

MV

1

55

55

BU

54

OG

CV

1

53

53

53

53

WH

6

BN

7

15

9

8

KRX

8

9

32

X

10

31

10

34

MP

KRX

22

24

21

17

14

1

14

19

16

KRX

A2

A1

BU

OG

16

15

2

20

SB

20

BK

BK

19

GN/YE

FV

U

BK

Czarny / 

Black

BN

Brązowy 

Brown

BU

Niebieski / 

Blue

GN/YE

Żółto-zielony /

Green-Yellow

GY

Szary / 

Grey

OG

Pomarańczowy

 / 

Orange

WH

Biały / 

White

min

med

max

Minimalna prędkość / 

minimum speed

Średnia prędkość / 

medium speed

Maksymalna prędkość /

maximum speed

CV1/CV2

Skraplacz / 

Condenser

FV

Warystor / 

Varistor

KRX

Przekaźniki alarmowe

 / 

Alarm relais

L

Faza / 

Phase

MP

Silnik pompki skroplin /

Drain pump motor

MV1/MV2

Silnik wentylatora / 

Fan motor

N

Zero / 

Neutral

PE

Uziemienie / 

Ground

Q1

Zabezpieczenie / 

Protection

QG

Zabezpieczenie / 

Protection

SB

Czujnik poziomu wody

 / 

Water level sensor

SM

Czujnik min. temperatury wody /

Sensor min. water temp.

X

Listwa zaciskowa /

Power terminal block

YC

Zawór 3-drogowy (4R) 

 /

3-way valve (4 T)

YF

Zawór 3-drogowy /

 

3-way valve

LISTWA ZACISKOWA KASETY

LISTWA ZACISKOWA KASETY

LISTWA ZACISKOWA KASETY

CHŁODZENIE /

COOL

CHŁODZENIE /

COOL

GRZANIE /

HEAT

Содержание TCW 104

Страница 1: ...ntażu obsługi i konserwacji Klimakonwektory kasetonowe Installation use and maintenance manual Cassette fan coil unit TCW Seria Series Wydajnie Edition Katalog Catalogue Zastępuje Superseedes CLM 28 TCW 42 104 04 06 ...

Страница 2: ...insructions must be given special attention if they are not observed there may be damage to the unit persons and things G I Holding S p A declines any responsibility for any damage caused by inattentive reading of this manual or by improper use of the unit For any abnormalities not covered by this manual please promptly contact technical customer service Attention Keep manuals in a dry place to av...

Страница 3: ...with float and detection at 3 levels On Off Alarm of con densation for lift in the upper part of the box Discharge occurs by gravity outside the appliance lift height up to 600 mm Drain discharge Condensate draining should be performed by gra vity according to the good practices a trap should be installed on the discharge pipe which must slope downwards Nachylenie 1 100 1 100 slop Podłączenie wężyk...

Страница 4: ...zględem sufitu podwie szanego a zwłaszcza musi zapewniać odstęp między wlotem i wylotem powietrza 2 2 Fresh air intake and treated air discharge in an adjacent room Prepunched openings at the side allow to install ducts to intake fresh air from the outside or to discharge towards an adjacent room 2 3 Fresh air intake Fresh air flow shouldnot exceed 12 of nominal air flow An anti frost thermostat pre...

Страница 5: ... the interna tional earth symbol UNIT FOR 2 AND 4 PIPES SYSTEM MODELS 42 54 Main layout the variants made in the constructions can involve modifi cations Always refer to the layout supplied with the product Jednostka dla systemu 2 rurowe go z zaworem lub bez z panelem sterowania DRM Unit for system with 2 pipes with or without valve with DRM con trol panel Jednostka dla systemu 4 rurowego z dwoma z...

Страница 6: ...ego z dwoma zaworami lub dla systemu 2 rurowego z zaworem lub bez grzałką elektryczną i panelem ste rowania DRA Unit for system with 4 pipes with two valves or with 2 pipes with or without valve and electric heater with DRA control panel CV2 53 KRX 230V 50Hz L PE 2 1 1 N QG 4 3 3 53 BU YF 55 56 GY BU 54 MV2 OG WH 12 BU 13 MAX 2 3 BN 14 4 15 11 56 4 5 MIN 54 55 BU MED YC 3 54 54 56 56 56 56 GY 55 5...

Страница 7: ...le set the speed selector in the desired position Note Control with the thermostat and minimum tem perature sensor prevent the fan coil unit from delivering into the room cold air in winter and hot air in summer mode auto 2 Obsługa i sterowanie Operation and control 2 9 Uruchomienie Po napełnieniu układu odpowietrz go Należy również odpowietrzyć klimakonwektor korzystając z właściwych zaworów oraz...

Страница 8: ...30 44 54 100 200 300 400 Pa 42 0 10 20 30 104 100 200 300 400 500 600 700 Pa 84 0 10 20 30 Funkcjonowanie kasety z zablokowanymi wylotami powietrza Closed air louvers 1 zamknięte żaluzje 2 Closed air louvers Kanał nawiewny Dostępny spręż Dostępny spręż Dostępny spręż Dostępny spręż Kanał nawiewny Kanał nawiewny Kanał nawiewny ...

Страница 9: ...n the unit use a cloth slightly dampened with water and alcohol at a maximum tempera ture of 45 C Dry with a soft cloth and use a brush to clean the grilles 4 2 Filter cleaning The unit is manufactured with modern tech nologies which ensure proper operation and maximum efficiency over time therefore the only regular maintenance to be performed is the cleaning of the air filter This cleaning will e...

Страница 10: ...emperaturę Nadmierna różnica między temperaturą w pomieszczeniu i temperaturą ustawioną w ramach sterowania automatycznego Zmniejsz różnicę temperatur Klimakonwektor nie uruchamia się Brak zasilania Sprawdź obecność napięcia Defect description Possible cause Possible solution Little air coming out of fan coil unit improper setting on control panel select correct speed filter clogged clean filter obs...

Отзывы: