5 ELECTRICAL CIRCUIT
AVOID THE RISK OF THE ELECTROCUTION !!!
Only qualified
persons should
attempt
installation,
troubleshooting
, and
repair.
Ensure that power to the system is disconnected before removing covers to electrical boxes
.
IMPORTANT NOTE
To avoid possible electrical shocks that
may
cause
injury
or death, the
Compact unit must be properly connected
to a safety ground
, as
follows
:
1- Use a
correctly sized
3-conductor
electrical cable with ground wire section and isolation
.
2- Use only marine grade cable with multi-strand tinned conductors. Do not use residential wire with solid conductors
3-
The ground wire must be correctly connected to the ground terminal of the panel.
4
- Check that the ground connection between the electrical box and the air-conditioner has
not
suffer
ed
from
da
mage during transport.
5
- Check that the
ground
connection of the water pump
is securely and properly
connected in the
electrical box
.
6
- Check the ground continuity
with a multi-meter
before switching off the air-conditioner.
WARNING
5.1 -
Vega II, Vega III, and FX II Controls
All electrical connections are made inside the Power Module box
.
See
control
Manual
s
for specific details.
5.2 - SUPPLY
Check that the available supply corresponds to the label on the unit, on the box and on the electrical pump.
Power should be supplied from a breaker of
the
correct rating
.
See spec sheet for details.
All electrical wiring must be marine grade, of the correct gage, and with multi-strand tinned conductors
.
All connections on the terminal strip
s
must be made with correctly sized
wire and/or
connectors
.
5 ELECTRICAL CIRCUIT