C - The 

return air grille should be located so that 

      there is unobstructed air space between it and

       the air intake on the unit

,

 as in picture 1.6.

 

D - 

Alternatively, the unit may be reversed, as in

 

     

picture 2.6.

 

3.3 - 

Unit Location

A.- The unit 

must be 

located in the area to be

conditioned. Typical

locations are under a 

setee or bunk. A Compact

unit must never be located

in an engine 

space

B.- The conditioned air must be 

ducted

 to one or more grills through

 ducts of suitable size,

 

either insulated or non-

i

n

s

u

lated.

View from above

Figure 1.6

Figure 2.6

View from above

3 INSTALLATION OF THE COMPONENTS

Содержание Compact 12

Страница 1: ...COMPACT SPLIT QUATTRO INSTALLATION MANUAL Climma Compact Units Cod A52040NA Aug 2011 ...

Страница 2: ... 07 Air filter 08 Remote control panel 09 Flexible duct 10 Transition 11 Discharge grille 12 Condensation drain hose 13 Sea water inlet hose 14 Sea water pump 15 Sea water ball valve shown closed 16 Sea water strainer 17 Scoop thru hull intake 18 Air intake 19 Air conditioner unit 20 Sea water discharge 08 17 16 15 14 13 12 06 11 10 04 18 09 07 19 20 05 ...

Страница 3: ...ce and heat is removed from the sea water and transfered to the air in the cabin Choosing the unit position it is necessary to consider the following elements 1 the accessibility to the air filter for cleaning 2 the necessary space for the fastening of the securing clips 3 the connection of the condensation drains 4 the connection of the duct to the duct ring on the unit 5 the connection of the se...

Страница 4: ... reversed as in picture 2 6 3 3 Unit Location A The unit must be located in the area to be conditioned Typical locations are under a setee or bunk A Compact unit must never be located in an engine space B The conditioned air must be ducted to one or more grills through ducts of suitable size either insulated or non insulated View from above Figure 1 6 Figure 2 6 View from above 3 INSTALLATION OF T...

Страница 5: ...lets as you can see in the picture above Either one or both drains may be used Condensate drains should ideally make a vertical orientation as soon as possible after the pan fitting If both drains are to be used they should be joined together at a point lower than the drain pan Do not make more than one U trap in the condensatebe drain as this can lead to a pneumatic lock that will prevent the dra...

Страница 6: ...se clog the fins on the air intake The Air Filter should be checked and cleaned periodically more often with high usage units and on vessels with an abundance of carpets and rugs and with pets on board 3 6 CONDENSATE DRAIN When the blower is operating the area surrounding the Compact unit becomes a low pressure area A trap in the drain Fig A will prevent odours from being sucked up and entering th...

Страница 7: ... grille sizing for Compact units is shown on the Compact spec sheet See spec sheet 3 9 Ducting When using flexible duct ensure that the duct maintains its diameter and is not crushed when passing through bulkheads and around tight corners 3 10 Air ducts Stretch flexible ducts so that the maximum internal diameter is maintained Cut duct to correct length and do not concertina duct which will reduce...

Страница 8: ...attempt to connect a duct of smaller diameter than the duct collar on the Compact unit The blower can be rotated 90 for installations with limited height Example of a Compact installation using a T or Y to split the duct to two or more discharge grilles The main grille must be of minimum area for size of unit see Compact spec sheet and non closeable Secondary grilles can be closeable ...

Страница 9: ...r pump so that its outlet is vertical and as far below the water line as possible Scoop intake strainer must point towards the bow The hose must make a continual rise from the ball valve through the strainer and into the pump inlet All items in the pump circuit must be as far below the water line as possible Use wire reinforced hose for this section and secure hoses using double stainless steel ho...

Страница 10: ...ATER CIRCUIT 4 4 SEA WATER CIRCUIT The water intake and discharge ports on the Compact unit are marked with arrows Correct water flow direction is important for efficient performance of the Compact unit Connections may differ from those shown Min 2 ...

Страница 11: ... 4 Check that the ground connection between the electrical box and the air conditioner has not suffered from damage during transport 5 Check that the ground connection of the water pump is securely and properly connected in the electrical box 6 Check the ground continuity with a multi meter before switching off the air conditioner WARNING 5 1 Vega II Vega III and FX II Controls All electrical conn...

Страница 12: ...t delay 7 MAINTENANCE For the efficient functioning of the air conditioner observe the following checks and maintenance Check sea water filter weekly Check air filter monthly Check and clean condensation drain every four months Clean condensation pan annually Check sea water intake whenever boat is hauled 7 1 CONDENSATE DRAIN During the cooling cycle air conditioners produce condensate water more ...

Страница 13: ...ulation sea water strainer and pump Consult the Manual for the control The compressor isn t operating The high pressure switch has operDWHG Check the sea water circuit switch the system off and then on again Consult the Manual for the control for more details 8 6 3 ODUP DSSHDUV RQ WKH LVSOD IN COOL MODE This indicates that the high pressure switch has operated more than three times due to insuffic...