In cooling mode the unit creates
warm moist exhaust air, which must
be conducted away from the room
to be cooled. For this reason it is
necessary to plug the exhaust air
hose into the outlet opening on the
rear of the unit.
•
Ensure that
the catches
for the
exhaust air
hose latch
securely
into the
two openings of the connection
aperture. Do not lay the flexible
exhaust air hose with tight
bends and do not kink it in
order to be sure of effective
operation and to avoid this
causing damage to air ducting
components!
•
The exhaust air of the unit
contains a certain amount of
moisture. For this reason it is
advisable to feed the exhaust
air to the outdoor area or to
outdoors.
Exhaust air routing variants
You can route the exhaust air out of
the building as follows:
Via a flat nozzle
The flat nozzle supplied can be used
in various different ways. It is pos-
sible to feed the flat nozzle through
an open window and fasten it by
means of Velcro and a window suc-
tion cup
(Fig. 4, page 15)
.
Likewise the flat nozzle can be hung
in a tilted window
(Fig. 6, page 15)
.
8.0 Before commissioning
The unit is positioned at the desired
location with the discharge side
pointing into the room. When
positioning, observe the following
notes.
•
After unpacking the unit let it sit
on its transport rollers for at least
5 minutes before you switch it
on.
•
Set the unit down in a stable
position on
a level and
firm floor. If
the floor is
uneven then
this can lead
to vibrations
and disturbing
noises.
•
Check whether
the stopper in
the condensate
drain is present
and correctly
installed. There
is a risk of
uncontrolled
condensate
leakage after
commission-
ing.
•
Never operate
the unit without
the air inlet
filter.
Otherwise, the
fins of the heat
exchanger can
become dirty
and the unit
loses performance.
•
Ensure that persons and sensitive
objects, such as plants, are not
placed directly in the air flow
emerging from the unit.
Recirculated air
filter
•
All extensions
to the power
supply must be
of a sufficient
cable size and
must only
be used fully
rolled out.
Conduct the warm exhaust air away
CAUTION!
There must be a minimum
clearance of 30 cm between the
rear of the unit and the wall.
OUR TIP
In addition, with direct solar
radiation close the curtains and
blinds and keep the windows and
doors closed during operation.
CAUTION!
The exhaust air hose should
always be laid rising in the
direction of air flow and must not
be extended.
Condensate emer-
gency drain with
stopper
Condensate
drainage with
stopper
CLIMIA