17
Home Arm mode, if an ―
Entry 1
‖
or ―
Entry 2
‖ device is triggered,
the Control Panel will start an
Entry Delay countdown timer
according to Entry 1 Delay or
Entry
2
Delay
setting
programmed for the user to
disarm the system. (please refer
to
5.4. Area
for detail)
If the delay period expires and
no correct PIN code has been
entered, the Control Panel will
activate
its
built-in
siren
immediately and follow
Entry
Timer Extend
setting. (please
refer to
2.7. General Setting
for
detail)
If Entery Timer Extend is set to
OFF, the Control Panel will
report
a
Burglar
Alarm
immediately.
If Entery Timer Extend is set to
ON, the Control Panel will wait
for 30 seconds before reporting
a
Burglar Alarm
. If the panel is
disarmed within 30 seconds, no
burglar alarm will be reported.
Away and Home Arm Entry
Delay:
When the system is counting
down Away or Home Entry
Delay Timer, if an ―
Entry 1
‖ or
―
Entry 2
‖ device is triggered, the
Control Panel will wait until the
Entry Timer expires before
activating a ―
Burglar Alarm
‖. If
the system is disarmed before
Entry Time expires, the Control
Panel will not respond.
Exit Delay:
When the system is counting
down Exit Delay Timer, if an
―
Entry1
‖ or ―
Entry 2
‖ device is
triggered, the Control Panel will
not respond.
Home/Delay
Away and Home Arm Mode
:
When the system is in Away
Arm mode, if a ―
Home/Delay
‖
device is triggered, a ―
Burglar
Alarm
‖
will
be
activated
immediately and reported.
When the system is in Home
Arm mode, if a ―
Home/Delay
‖
device is triggered, the Control
Panel will start an Entry Delay
countdown timer according to
Entry
1
Delay
setting
programmed for the user to
disarm the system. (please refer
to
5.4. Area
for detail)
If the delay period expires and
no correct PIN code has been
entered, the Control Panel will
activate
its
built-in
siren
immediately and follow
Entry
Timer Extend
setting. (please
refer to
2.7. General Setting
for
detail)
If Entery Timer Extend is set to
OFF, the Control Panel will
report
a
Burglar
Alarm
immediately.
If Entery Timer Extend is set to
ON, the Control Panel will wait
for 30 seconds before reporting
a
Burglar Alarm
. If the panel is
disarmed within 30 seconds, no
burglar alarm will be reported.
Away and Home Arm Entry
Delay:
When the system is counting
down Away or Home Entry
Delay Timer, if a ―
Home/Delay
‖
device is triggered, the Control
Panel will wait until the Entry
Timer expires before activating
a ―
Burglar Alarm
‖. If the system
is disarmed before Entry Time
expires, the Control Panel will
not respond.
Exit Delay:
When the system is counting
down Exit Delay Timer, if a
―
Home/Delay
‖
device
is
triggered, the Control Panel will
not respond.
Silent Burglar
When the system is in Away and
Home Arm mode, or counting
down Entry / Exit Delay Timer, if
a ―
Silent Burglar
‖ device is
triggered, the Control Panel will
report a ―
Burglar Alarm
‖ but will