7.2. Report
If the Motion Detection function is Enabled in
5.2. Motion Detection
, the IP Camera will
report CID event code via IP to programmed location upon motion detection. Use the
Report
webpage to program the report destination setting.
Reporting URL
Enter URL destination(s) using the following format:
ip://Account Number@ServerIp:Port/CID
Account number must be between 4-6 digits.
Level
Select a reporting condition:
Please select “
All events
” for this option.
Group
Select a group for your report destination The system will make report according to
the following settings:
Group with higher priority will be reported first: Ex: Group 1
Group 2
Group
3….
If reporting to the first destination in a group fails, the system will move on to the
next report destination in the group.
If reporting to one of the report destinations in a group is successful, the system
will consider reporting to this group successful and stop reporting to rest of the
destinations in the group. It will then move on to report to the next group.
If reporting to all destinations in a group fails, the system will retry the reporting
according to retry times set below. If reporting is still unsuccessful after retries,