65
6.1.5.1 Alarm Report Procedure
Mobile Lite alarm and location reporting sequence is determined by
Use Last
Position
setting.
Use Last Position
Disabled
When Mobile Lite button is pressed and alarm is activated, it will begin to
acquire new Location (through Wi-Fi and GPS positioning) and count down
Guard Time.
If new Location is acquired within Guard Time, Mobile Lite will make
alarm report (event code 100/101/120) along with location
coordinates when Guard Time expires.
If new Location is not acquired by the time Guard Time expires,
Mobile Lite will make alarm report (event code 100/101/120) with no
location info.
After new position is acquired, Mobile Lite will follow up with another
report in event code 645.
If new position is acquired, and
it’s in two-way communication
following a successful IP report, Mobile Lite will make report in event
code 100/101/120 with location info via the previously successful IP
channel. Mobile Lite will keep updating and reporting location info
every minute in event 100/101/120 before two-way communication
ends.
Example:
1. If Guard Time = 30 seconds, new Location acquired within Guard Time:
Mobile Lite makes alarm report (CID 100/101/120) upon Guard Time
expiry along with new Location coordinates.
2. If Guard Time = 30 seconds, new Location is NOT acquired within Guard
Time:
Mobile Lite makes alarm report (CID 100/101/120) upon Guard Time
expiry without Location coordinate.
a. When new position is acquired, Mobile Lite makes follow up report
(CID 645) immediately with Location coordinates.
b. If new position is acquired under two-way communication following a
successful IP report, Mobile Lite makes report (CID 100/101/120) via
the successful IP channel with location coordinates.
During the two-way communication, Mobile Lite will keep updating
location and making report (CID 100/101/120) every minute.
Use Last Position
Enabled
When this function is Enabled, Mobile Lite will regularly scan for nearby