Page 65
3. Reset the emergency stop by pulling the button up.
4. Check that the machine doesn’t restart.
5.3.4
Pneumatic conditioning unit drop-out circuit check
The pneumatic conditioning unit drop-out circuit prevents the machine from restarting
unexpectedly after air supply to the PCU is lost and restored.
To check the PCU drop-out circuit:
1. Check that the PCU is connected to an air supply and to the FF6300.
2. Check that the air-supply lock-out is open (pulled up).
3. Press the START button.
4. Slowly open the PCU speed adjustment valve until the rotary drive engages.
5. Close (press down) the lock-out valve.
6. Check that the FF6300 stops.
7. Open the lock-out valve.
8. Verify that the machine does not automatically restart when the lock-out valve
is re-opened in step 7.
WARNING
Do not
operate the machine if the pneumatic conditioning unit starts in step
8. Contact CLIMAX for service recommendations.
5.3.5
Hydraulic power unit maintenance
1. Refill the HPU oil reservoir before each use.
2. Replace the oil and filter every two years.
For more information on HPU maintenance, see the HPU operator’s manual that was
included with the FF6300.
5.3.6
Dovetail and square ways maintenance
Lightly lubricate the dovetail and square ways after cleaning and after each work
session. This helps protect the machine precision surfaces from corrosion. See
Figure A-6 on page 86 and Figure A-10 on page 90 for the locations of the dovetail
and square ways.
5.3.7
Leadscrew maintenance
1. Lightly lubricate the leadscrew after cleaning, after each work session, and
periodically during operation to ensure smooth travel. For leadscrew locations,
see Figure A-6 on page 86 and Figure A-10 on page 90.
2. During operation, clean ball screws and ACME leadscrews frequently to pre-
vent thread damage to nut and leadscrew.
Содержание FF6300
Страница 2: ......
Страница 4: ...Page B FF6300 Operating Manual CLIMAX GLOBAL LOCATIONS...
Страница 5: ...P N 80679 Rev 10 Page C CE DOCUMENTATION...
Страница 10: ...Page iv FF6300 Operating Manual This page intentionally left blank...
Страница 14: ...Page viii FF6300 Operating Manual This page intentionally left blank...
Страница 16: ...Page x FF6300 Operating Manual This page intentionally left blank...
Страница 21: ...P N 80679 Rev 10 Page 5 This page intentionally left blank...
Страница 28: ...Page 12 FF6300 Operating Manual This page intentionally left blank...
Страница 31: ...P N 80679 Rev 10 Page 15 2 1 1 ID chuck assembly FIGURE 2 1 ID CHUCK ASSEMBLY...
Страница 32: ...Page 16 FF6300 Operating Manual 2 1 2 ID chuck assembly dimensions FIGURE 2 2 ID CHUCK ASSEMBLY DIMENSIONS...
Страница 33: ...P N 80679 Rev 10 Page 17 2 1 3 OD mount assembly FIGURE 2 3 OD MOUNT ASSEMBLY...
Страница 34: ...Page 18 FF6300 Operating Manual 2 1 4 OD mount assembly dimensions FIGURE 2 4 OD MOUNT ASSEMBLY DIMENSIONS...
Страница 40: ...Page 24 FF6300 Operating Manual This page intentionally left blank...
Страница 71: ...P N 80679 Rev 10 Page 55 FIGURE 3 44 BACKFACING ATTACHMENT DIMENSIONS...
Страница 72: ...Page 56 FF6300 Operating Manual This page intentionally left blank...
Страница 88: ...Page 72 FF6300 Operating Manual This page intentionally left blank...
Страница 90: ...Page 74 FF6300 Operating Manual FIGURE 6 1 FF6300 IN CONTAINERS STEEL CONTAINER WOODEN CRATE...
Страница 92: ...Page 76 FF6300 Operating Manual FIGURE 6 3 PACKING THE FF6300 WITH OD MOUNT...
Страница 94: ...Page 78 FF6300 Operating Manual This page intentionally left blank...
Страница 99: ...P N 80679 Rev 10 Page 83 This page intentionally left blank...
Страница 126: ...Page 110 FF6300 Operating Manual This page intentionally left blank...
Страница 128: ...Page 112 FF6300 Operating Manual FIGURE B 3 HYDRAULIC KIT 6 2 CUBIC IN MOTOR WITH QD FTG FF6300 P N 80970 HPU HYD MOTOR...
Страница 129: ...P N 80679 Rev 10 Page 113 APPENDIX C SDS Contact CLIMAX for the current Safety Data Sheets...
Страница 130: ...Page 114 FF6300 Operating Manual This page intentionally left blank...
Страница 131: ......
Страница 132: ......