Page 52
BW3000 Operating Manual
Checking the flow rate.
The shielding gas flow rates should not exceed 35 cfh.
To check the flow rate, press the PURGE button. The gas solenoid will open for 10
seconds, allowing you to check the flow rate and also clear unwanted gases from
the system.
4.3
P
RE
-
WELD
CHECKLIST
4.4
S
TARTING
,
STOPPING
,
AND
INTERRUPTING
THE
WELD
PROCESS
4.4.1
Starting to weld
To start welding, press the
WELD
button on the control box.
If stubbing occurs, raise the voltage until the process stabilizes.
After the first rotation, you should be able to view the placement of the weld bead
in relation to the previous bead and the base metal. As described in Section 4.2.2
on page 50, the correct step is attained when the weld is evenly placed between the
previous bead and base metal.
Normally, only adjustments to step, wire speed, and voltage are necessary to main-
tain the required weld deposits and feed necessary for successful borewelding.
WARNING
Use the appropriate light shield when making any visual inspection.
Avoid both direct and indirect exposure to arc rays.
T
ABLE
4-6. P
RE
-
WELD
CHECKLIST
Weld positive is connected to the BoreWelder and weld power supply.
Weld negative is connected to part and weld power supply.
Rotation speed is set (using
ROTATION
SPEED
).
Wire speed is set (using
WIRE
SPEED
).
Step is set (using
STEP
SIZE
).
Voltage is set (using
ARC
VOLTAGE
).
Shielding gas is connected and on (using
PURGE
).
Torch is at the rotation initialize point (using step point).
Twisted wire is fed out from BoreWelder (using
WIRE
JOG
).
Quill is retracted to the correct position to start the weld (using
RETRACT
).
Содержание AUTOBOREWELDER BW3000
Страница 1: ...BW3000 BW3000 AUTOBOREWELDER OPERATING MANUAL P N 52815 February 2019 Revision 7 ...
Страница 2: ......
Страница 4: ...Page B BW3000 Operating Manual CLIMAX GLOBAL LOCATIONS ...
Страница 6: ...Page D BW3000 Operating Manual This page intentionally left blank ...
Страница 10: ...Page iv BW3000 Operating Manual This page intentionally left blank ...
Страница 14: ...Page viii BW3000 Operating Manual This page intentionally left blank ...
Страница 22: ...Page 8 BW3000 Operating Manual This page intentionally left blank ...
Страница 46: ...Page 32 BW3000 Operating Manual This page intentionally left blank ...
Страница 60: ...Page 46 BW3000 Operating Manual This page intentionally left blank ...
Страница 105: ...P N 52815 Rev 7 Page 89 This page intentionally left blank ...
Страница 140: ...Page 124 BW3000 Operating Manual FIGURE B 1 BOREWELDER WITH METAL OR PLASTIC CONNECTORS SCHEMATIC P N 87413 ...
Страница 141: ...P N 52815 Rev 7 Page 125 FIGURE B 2 WIRE FEEDER WITH METAL CONNECTORS SCHEMATIC P N 87414 ...
Страница 142: ...Page 126 BW3000 Operating Manual FIGURE B 3 WIRE FEEDER WITH PLASTIC CONNECTORS SCHEMATIC P N 87415 ...
Страница 143: ...P N 52815 Rev 7 Page 127 FIGURE B 4 POWER SUPPLY INTERFACE CABLE WITH PLASTIC CONNECTOR SCHEMATIC P N 87419 ...
Страница 144: ...Page 128 BW3000 Operating Manual FIGURE B 5 POWER SUPPLY INTERFACE CABLE SCHEMATIC WITH PLASTIC CONNECTOR P N 87421 ...
Страница 145: ...P N 52815 Rev 7 Page 129 FIGURE B 6 METAL CONNECTORS SYSTEM LAYOUT P N 70186 1 ...
Страница 146: ...Page 130 BW3000 Operating Manual FIGURE B 7 METAL CONNECTORS LADDER SCHEMATIC P N 70186 2 ...
Страница 147: ...P N 52815 Rev 7 Page 131 FIGURE B 8 CHART CONTROLLER WITH METAL CONNECTORS P N 70186 3 ...
Страница 148: ...Page 132 BW3000 Operating Manual This page intentionally left blank ...
Страница 149: ......
Страница 150: ......