Features 

 

LED Indicator   

In Normal operation mode, the LED indicator remains off except in the following situations: 

 

When Door Contact’s Tamper switch is triggered. 

 

When the Door Contact is activated with either Tamper or Low battery condition. 

 

When the Door Contact is activated and transmitting the signal under the Test mode. 

If the LED flashes to indicate signal transmission, it will flash twice rapidly upon receiving acknowledgement 
from the Control Panel. 

 

Supervision   

 

The Door Contact will automatically transmit Supervisory signals periodically to the Control Panel at 
random intervals of 15 to 18 minutes in Normal Operation Mode. 

 

If the Control Panel has not received the signal from the Door Contact for a preset period of time, the 
Control Panel will indicate that particular Door Contact is experiencing an out-of-signal problem. 

 

Tamper Switch   

 

The Door Contact is protected against any attempt to open the device cover or to detach the device 
from its mounting surface. 

 

If the Door Contact detects a tamper condition of cover opening or device removal, a tamper signal will 
be sent to the Control Panel to remind the user of the condition.   

 

Battery 

The MDC-5 uses one 

3V CR2450 Lithium battery

 as its power source. The Door Contact is also capable of 

detecting low battery. When the battery is low, a low battery signal will be sent to the Control Panel along with 
regular transmission. The LED will light up when the Door Contact is activated under low battery status.   

 

Installing / Changing Battery 

       

Step 1. Slide the cover to the left to open it.   

Step 2. Once the cover is opened, you can proceed to install / change the     

battery. 

Step 3. For changing battery, after the old battery has been removed, press the 

Learn / Test button 5-6 times to fully discharge 

Step 4. Inset new battery with the positive side (+) facing up. 
Step 5. Remove the door contact retaining screw that is installed on the 

bottom-right corner of the door contact (See 

Figure 1

 above for details). 

Step 6. Replace the cover:   
Step 7. Use the retaining that was just removed to secure the cover and the door 

contact.   

 

Test Mode 

 

The Door Contact can be put into Test mode for 3 minutes by pressing the Test 
Button once. 

 

Under Test Mode, the LED will light up whenever the Door Contact is activated.   

 

Each additional Test Button press will reset Test Mode time to 3 minutes. 

 

Getting Started 

Step 1: Open the cover and insert the battery. 

 

The door contact retaining screw is 

installed on the bottom-right corner of 
the door contact by factory. 

You can remove it from the door 

contact, and use it as a top retaining 
screw to secure the cover and the door 
contact. 