Data measured in the following conditions:
(1) Heat pump operation: Outside air temperature 7°C DB- 6°C WB, water inlet 30°C and outlet 35°C
(2) Heat pump operation: Outside air temperature 7°C DB- 6°C WB, water inlet 40°C and outlet 45°C
(3) Chiller operation: Outside air temperature 35°C DB, water inlet 18°C and outlet 23°C
(4) Chiller operation: Outside air temperature 35°C DB, water inlet 12°C and outlet 7°C
(5) Noise measured at 1 metre in an open field
The power input does not include the water circulating pump.
AWR MT
0011
0025
0031
0041
0031
0041
0051
0061
Heating capacity (1)
kW
6,7
8,7
11
14
10,9
14,5
16,4
18,3
Power input (1)
kW
1,6
2
2,6
3,2
2,5
3,2
3,9
4,1
C.O.P.
4,19
4,35
4,23
4,38
4,36
4,53
4,21
4,46
Heating capacity (2)
kW
6,5
8,5
10,8
13,7
10,6
14,2
15,8
17,8
Power input (2)
kW
1,9
2,6
3,3
4
3,1
4,1
4,6
5
C.O.P.
3,42
3,27
3,27
3,43
3,42
3,46
3,43
3,56
Rated water flow (1)
m
3
/h
1,15
1,5
1,89
2,41
1,87
2,49
2,82
3,15
Useful pressure head (1)
kPa
60
88
75
53
75
53
54
40
Cooling capacity (3)
kW
6,5
8,4
11,8
14
11,9
14,5
16,9
18,7
Power input (3)
kW
1,9
2,7
3,3
4,1
3,1
4,2
4,7
5,5
E.E.R.
3,42
3,11
3,58
3,41
3,84
3,45
3,6
3,4
Cooling capacity (4)
kW
4,9
6,3
8,9
10,7
8,9
11,1
12,7
14,3
Power input (4)
kW
1,8
2,6
3,2
4
3
4,1
4,6
5,2
E.E.R.
2,72
2,42
2,78
2,68
2,97
2,71
2,76
2,75
Rated water flow (3)
m
3
/h
1,12
1,44
2,03
2,41
2,05
2,49
2,91
3,22
Useful pressure head (3)
kPa
68
93
75
55
75
55
56
37
No. of fans
no.
1
1
2
2
2
2
2
2
Air flow
m
3
/s
1
1,1
1,9
1,8
1,9
1,8
1,9
1,9
Type of compressor
SCROLL
Number of compressors
no.
1
1
1
1
1
1
1
1
Number of circuits
no.
1
1
1
1
1
1
1
1
Refrigerant R410A
Kg
3,2
3,1
3,1
3,1
4,1
4,1
4,8
4,8
Oil Mobil EAL ARTIC 22cc
Kg
1,1
1,24
1,25
1,66
1,25
1,95
1,66
1,77
Type of pump
Circular
Number pumps
no.
1
1
1
1
1
1
1
1
Operating weight
kg
125
150
155
165
155
165
175
180
Water fittings
inches
1 -3/4
1 -1 1/4
1 1/4
1 1/4
1 1/4
1 1/4
1 1/4
1 1/4
Sound power EN ISO 3744
dB(A)
70
72
72
72
72
72
72
72
Sound pressure (5)
dB(A)
55
58
58
58
58
58
58
58
Power supply
V/ph/Hz
230~50
400-3N~50
GENERAL TECHNICAL DATA
I A