![CLIMAVENETA Accurate AD Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/climaveneta/accurate-ad/accurate-ad_installation-user-maintenance-manual_2624838014.webp)
HOT WATER RE-HEATING
14
EN
ACCURATE AX - AW - AD - AT - AF
4 - water IN / OUT 70°C/60°C, air 20°C
6 - water IN / OUT 45°C/40°C, air 20°C
Post reheating system by mean hot water, composed by finned coil with copper tubes, 3 way valve and actuator driven with the logic imple-
mented in EV controller
PERFORMANCE
Frame
F1
F2
F3
F4
F5
F6
Models
05
07
10
15
18
20
26
29
39
30
40
50
55
60
70
80
90
Heating Capacity (4)
kW
8,5
10,4 10,4 20,2 20,2 14,4 16,1 16,1 28,7 25,0 28,7 28,7 39,3 39,3 39,3 41,6 41,6
Water Flow (4)
l/h
727
910
910 1780 1780 1270 1410 1410 2520 2190 2520 2520 3450 3450 3450 3570 3570
Total pressure drops (4)
kPa
10
15
15
30
30
16
19
19
46
36
46
46
40
40
40
27
27
Heating Capacity (6)
kW
4,2
5,1
5,1
9,9
9,9
7,0
7,9
7,9
14,1 12,3 14,1 14,1 19,3 19,3 19,3 20,5 20,5
Water Flow (6)
l/h
714
890
890 1730 1730 1220 1370 1370 2460 2150 2460 2460 3350 3350 3350 3560 3560
Total pressure drops (6)
kPa
10
15
15
29
29
15
19
19
47
37
47
47
39
39
39
28
28
Water connectionsi
inch 1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
3/4
3/4
3/4
3/4
3/4
3/4
3/4
1
1
HOT GAS REHEATING COILS
(1) Operating conditions: Air 24°C/50% RH - Condensing temperature 45 °C
PERFORMANCE
Frame
F1
F2
F3
F4
F5
F6
Models
05
07
10
15
18
20
26
29
39
30
40
50
55
60
70
80
90
Type
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
ON/OFF
Heating Capacity (1)
kW
4,4
5,1
5,1
10,1 10,1
8,4
9,3
9,3