SPECIFICATIONS 

DEHUMIDIFIER 

Model No.: OL-R230SP

 

Voltage & Hertz 

AC115V / 60Hz 

Power Consumption& Current 

945W/8.3A @80

, 60% RH 

1140W/10.6A @86

, 80% RH 

Refrigerant Charge 

R410A/26.8oz (760g) 

Dehumidify Capacity 

130Pints/Day @80

, 60% RH 

200Pints/Day @86

, 80% RH 

Maximum Design Pressure 

High Side: 522psig (3.6MPa) 

Low Side: 240psig (1.65MPa) 

BCSC 

15A 

Compressor Input 

RLA: 9.1A    LRA:50.5A 

Fan Motor Power 

0.187HP 

Date Code 

 

 

 

 

 

 

FEATURES 

Movable,  Easy  for  Storage:

 

The  unit  is  equipped  with  durable  rubber 

wheels and can be stacked for storing.

 

Wide Operating Temperature Range:

 

The machines operating range is 

33

 to 100 

.

 

Timer: 

The unit can be programmed to operate on a timer.   

Energy-saving Design: 

Low power consumption design.

 

Auto Drainage and Manual Drainage. 

Unit is equipped with a built-in 

pump for pumping condensate or optional manual drain. 

Содержание REVOLT LGR 5000

Страница 1: ...INSTRUCTION MANUAL REVOLT LGR 5000...

Страница 2: ...Please keep this manual for further reference CONTENTS CAUTIONS 1 SPECIFICATIONS 2 FEATURES 2 DRAWINGS 3 OPERATIONS 4 AUTO DRAINAGE AND MAINTENANCE 6 TROUBLE SHOOTING GUIDE 7...

Страница 3: ...ice issues 7 This appliance should only be used by adults who have read the manual and understand the operating procedure of the unit 8 The appliance is not to be used by persons including children wi...

Страница 4: ...sig 1 65MPa BCSC 15A Compressor Input RLA 9 1A LRA 50 5A Fan Motor Power 0 187HP Date Code FEATURES Movable Easy for Storage The unit is equipped with durable rubber wheels and can be stacked for stor...

Страница 5: ...3 DRAWINGS Front Back Power Cord Air Inlet Fordable Handle Air Outlet Water Hose Connector Rubber Wheel Logo Area Control Panel Auto Drain Connection Winder...

Страница 6: ...nute later Timer Button Press and hold the timer button for 3 seconds to increase the timer setting hour by hour and users can decrease the timer setting by pressing the purge button When the machine...

Страница 7: ...temperature When the machine is in standby mode press the power button for 5 seconds to switch to Fahrenheit temperature When the machine is running it shows the temperature and humidity of the inlet...

Страница 8: ...he electronic components of the unit Do not use chemical solvent such as benzene alcohol gasoline or other heavy duty cleaner The surface may become damaged or deformed Cleaning the Air Filter Step 1...

Страница 9: ...emperature and humidity sensor breakdown Replace it Error Code E4 Water pump failure Replace it Error Code E5 4 way valve failure Replace it Cautions If unit malfunctions turn off the unit and unplug...

Отзывы: