7
2. Transport and store the machine upright.
3. Stack machines in warehouse to save space.
TROUBLE SHOOTING GUIDE
Trouble
Possible Cause
Solution
Error Code: E1 Copper head sensor breakdown
Replace it
Error Code: E2
Air inlet temperature and humidity
sensor breakdown
Replace it
Error Code: E3
Air
outlet
temperature
and
humidity sensor breakdown
Replace it
Error Code: E4 Water pump failure
Replace it
Error Code: E5 4-way valve failure
Replace it
Cautions:
If unit malfunctions turn off the unit and unplug it immediately. Please
contact your distributor for service issues.
Do not dispose of electrical appliances in local landfills, or
municipal waste locations. Many parts are recyclable.
Contact your local government for information regarding the
collection systems available in your area.