OPERATION MANUAL
7
INSTALLATION (cont.)
Plugging in the Unit
1.
Check the prongs and surface of the power cord plug for dust/dirt. If dust and/or dirt
are present, wipe off with a clean, dry cloth.
2.
Check the power cord, plug and prongs for damage. If any damage is found, contact
ClimaTemp Portables or a qualified technician for repair.
WARNING:
1.
If the power cord or plug is damaged, replacement should only be performed by
qualified electrical personnel.
2.
Because of potential safety hazards under certain conditions, we strongly
recommend against the use of an extension cord.
Procedure for Testing Device
The CPT-12 is equipped with a LCDI power cord. This device is non-serviceable and
opening the device may cause electric shock or void the warranties of the product.
1. Plug into grounded appropriate 115v receptacle.
2. If unit does not operate, press the test button, followed by the reset button.
3. If test fails then do not use and contact your ClimaTemp reseller for replacement.
CAUTION: The power source should be a dedicated single outlet circuit with UL listed
short-circuit and ground fault protective breaker. Do not share the AC outlet with any
other instrument or equipment. The minimum power supply rating and the maximum
fuse size for each corresponding model are listed below.
MODEL
MINIMUM POWER SUPPLY RATING
RECOMMENDED
FUSE SIZE
CPT-12
115V, single phase,60Hz,15A
15A maximum